L
NAPCO Security Systems
X
GEM-P1632 Programming Instructions
!
Page 5
EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM - PRELIMINARY INFORMATION
!
Only Keypad #1 may be used for both Dealer and User programming, however this keypad may be located in any area.
!
The Default Dealer Code is
4
5
6
7
8
9
. Use this code to enter the Dealer Program Mode to
program a custom Dealer Code, which replaces the Default Dealer Code. If you clear your Dealer Code, use the Default Dealer
Code once again to enter programming.
!
After entering codes or data, press the save
U
button.
Data will not be stored into memory unless
U
is pressed
.
!
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
!
Silence the sounder by the
G
button to continue, or by pressing the
C
button to exit.
!
A panel that has been COLD STARTED (Address Location 1198) performs identically to a new panel.
!
When programming a Multiple Area System, Direct Address Programming Mode must be used to complete the program.
KEYPAD #1:
For ease of programming, it is recommended that a GEM-RP1CAe2 or GEM-K1CA be used as Keypad #1. (Regardless
of which keypad is selected, all
new
keypads are configured as Keypad #1 out of the box). If a GEM-RP2ASe2/GEM-K2AS is used,
configure address jumpers as Keypad #1 (see Configuring the GEM-RP2ASe2/GEM-K2AS Keypad, page 43).
1. Press
456789 R
2. Press
"PRIOR/NO" button until
“
TURNON PROG Y/N
”
(GEM-RP2ASe2/
GEM-K2AS) or
“
17
”
(GEM-RP3DGTL/GEM-K3DGTL or
GEM-RP4RFC/GEM-K4RF) appears on the LCD screen.
3. Press
"NEXT/YES" button to Enter Dealer Program Mode.
4. Press
CC
to exit Dealer Program Mode when finished.
Dealer Code (Default = 456789)
•
Number of Zones in Area 1
•
Panel Zone Doubling
•
Fire Zones in Area 1
•
2-Wire Fire Zones in Area 1
•
Local or Central Station Reporting System
•
Exit/Entry Zones in Area 1
•
Interior Zones in Area 1
•
24 Hour Zones in Area 1
•
Chime Zones in Area 1
•
Chime 2 Zones in Area 1
•
Exit/Entry2 Zones in Area 1
•
50mS Loop Response Zones
(Note: 750mS is
required for Loop Response time in UL installations).
•
Aux Output Activated on Alarm Zones
•
Sensor Watch Zones
•
Keypad Sounder on Alarm Zones
•
Auto Bypass re-entry Zones
•
Enable no EOLR Zones
•
Number of Keypads in Area 1
•
Central Station Receiver 1 Tel. Number
•
Central Station Receiver 1 Account Number
•
Central Station Receiver 1 Format
•
Enter User Codes
•
RF Transmitter Points
•
Quick Method
•
Key Fob Transmitters
•
Enter Zone Descriptions
•
Dealer Code
•
Enable Telco Line Fault Test
•
Enable Burg Output Chirp on Keyfob
•
Enable CP-01
•
Clear Dealer Program
•
Cold Start
NEW PANELS:
The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default
program, (a) from the Dealer Program Mode, press the
C
button to enter the Direct Address Program Mode; (b) access Location
1197 (Clear Program); (c) press the
U
button and start over.
Ea
s
y Me
nu Dri
ve
n
Pr
ogr
am Mode
ACCESSING DEALER PROGRAM MODE
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has
been loaded, you may alter it as necessary in the Direct Address Program Mode.