GEM-P1632 Programming Instructions
!
Page 13
GEM-RP3DGTL/GEM-K3DGTL and GEM-RP4RFC/GEM-K4RF Keypad Easy Program Menu
Enter the Default Dealer Program Code ("456789") for a new panel or enter your custom Dealer Program Code if
programmed.
Press
R
, followed by [PRIOR/NO] repeatedly until “17” is displayed
(
you can scroll back by pressing
B
).
Press [NEXT] to enter Dealer Program Mode. For the GEM-RP3DGTL/GEM-K3DGTL (and GEM-RP4RFC/GEM-
K4RF), questions are in the form of a 2-digit number flashing in the display. Press
R
to set the cursor into the next field to
answer the question. Press
R
again to scroll through each segment. Press [NEXT] to go to the next question. To review
your Easy Program Mode responses (before pressing
U
to save), press
R
until the 2-digit question number flashes in the display again.
If the data is correct, press
U
to save. If the data is incorrect, press
R
to set the cursor into the next field and again enter your data.
Note:
Review your Easy Program Mode responses after the initial programming of the control, except for questions marked "For New Panel
Only". These questions set up the basic structure of the panel program ("Number of Zones in an Area", etc.) and cannot be viewed or altered
once set. To exit the Dealer Program Mode, press
C
twice to resume normal keypad operation. To return the panel to the factory default,
enter the Direct Address Program Mode, go to location 1198 and press
U
.
Total Number of Zones
(Appears for New Panel Only)
Directly enter the total number of zones to be programmed. Valid entries are from 01 to 32. Directly
enter the total number of zones, including leading zeros. Use number buttons
1
through
9
.
NOTE:
Press the
0
button for a zero. The system is based on groups of 4 zones each (after the
first 8 zones), and will automatically round up to the next group of 4. For example, if you enter 13, it will
automatically convert this to 16 zones. Press
U
to save. Press the NEXT/YES button to proceed.
Panel Zone Doubling
(New Program Only)
•
To double the number of hardwired panel zones from 8 to 16, press the NEXT/YES button.
•
If Panel Zone doubling is not desired, press the PRIOR/NO button.
•
The 16 zones will remain EOL terminated zones, requiring Normally Closed devices only.
•
Refer to Wiring Diagram and Installation Instructions for wiring instructions
Fire Zones
(Appears for New Panel Only)
Enter the zone number of any Fire Zones (both 2-wire, 4-wire or wireless). Valid entries are from 01 to
32. Directly enter each zone number, including leading zeros, and press
U
to save, and then repeat
for any additional zone(s). Press the NEXT/YES button to proceed.
NOTE:
If you are programming a two Area system, enter the zone number of zones required for Areas
1 & 2. The Direct Address Program Mode can then be used to remove zones from Area 1 and place
them in Area 2. See Zone Options.
2-Wire Fire Zones
(Appears for New Panel Only)
Enter the zone number of any Fire Zones (from previous question) which are to be used with 2-wire
smoke detectors. The only valid entries are 07 and 08. Directly enter each zone number, including
leading zeros. Press
U
to save, and then repeat for any additional zone.
NOTE:
Only zones which
have been designated as Fire Zones can be programmed as 2 Wire Fire zones. Press the NEXT/YES
button to proceed.
NOTE:
JP7 must be set to “2-WF” position for 2-wire fire zones 7 and 8 (refer to
Installation Instructions).
Local System or C.S. Reporting System
(Appears for New Panel Only)
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for no zones to report
(LOCAL SYSTEM).
Exit/Entry Zones
(Appears for New Panel Only)
Directly enter the zone numbers which are to be used as Exit/Entry zones. Valid entries are from 01 to
32. Directly enter each zone number, including leading zeros. Use number buttons
1
through
9
.
NOTE:
Press the
0
button for a zero. Press
U
to save and then repeat for any additional
zone(s). Press the NEXT/YES button to proceed.
NOTE:
Exit/Entry Zones will have an entry delay of 30 seconds and an exit delay of 60 seconds.
R
COMPUTERIZED SECURITY SYSTEM
ARMED
STATUS
SYSTEM ARMED
01/01/97 12:00AM
1 2
4
3
5 6
7 8 9 0
A
B
C
D
E
F
G
NEXT/YES
PRIOR/NO
AREA
GEMINI
ENT A1
17
INT ERIOR
BY PASS
F IRE/T B L
SY S T BL
CHIM E
GEM-
RP3DGTL/GEM-K3
DGTL A
N
D
GEM-RP4RFC/GEM
-K
4RF Ea
s
y Me
nu Dri
ven
Pr
ogr
am Mode
(Press YES or NO)
06
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
(Direct Entry)
07
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
(Direct Entry)
05
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
(Direct Entry)
04
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H
(Direct Entry)
01
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
Flashing
(Press YES or NO)
03
INTERIOR BYPASS FIRE/TBL SYS TBL CHIME
H