STEP 2:
AREA OPTIONS:
Each relay event can be assigned to Area 1, Area 2 or both Area 1 &
Area 2.
!
Select the area from
Table 2
(shown on next page); enter in corresponding right digit address
location (left digit is not used).
EXTERNAL RELAY CONTROL (ADDRESS 0750-0829)
ADDRESS 0750-0754 (RELAY EVENT 1)
0750
0751
0752
0753
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0754
RELAY # AREA Timeout Event ID COND.
ADDRESS 0755-0759 (RELAY EVENT 2)
0755
0756
0757
0758
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0759
RELAY # AREA Timeout Event ID COND.
ADDRESS 0760-0764 (RELAY EVENT 3)
0760
0761
0762
0763
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0764
RELAY # AREA Timeout Event ID COND.
ADDRESS 0765-0769 (RELAY EVENT 4)
0765
0766
0767
0768
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0769
RELAY # AREA Timeout Event ID COND.
ADDRESS 0770-0774 (RELAY EVENT 5)
0770
0771
0772
0773
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0774
RELAY # AREA Timeout Event ID COND.
ADDRESS 0775-0779 (RELAY EVENT 6)
0775
0776
0777
0778
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0779
RELAY # AREA Timeout Event ID COND.
ADDRESS 0780-0784 (RELAY EVENT 7)
0780
0781
0782
0783
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0784
RELAY # AREA Timeout Event ID COND.
ADDRESS 0785-0789 (RELAY EVENT 8)
0785
0786
0787
0788
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0789
RELAY # AREA Timeout Event ID COND.
ADDRESS 0790-0794 (RELAY EVENT 9)
0790
0791
0792
0793
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0794
RELAY # AREA Timeout Event ID COND.
ADDRESS 0795-0799 (RELAY EVENT 10)
0795
0796
0797
0798
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0799
RELAY # AREA Timeout Event ID COND.
ADDRESS 0800-0804 (RELAY EVENT 11)
0800
0801
0802
0803
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0804
RELAY # AREA Timeout Event ID COND.
ADDRESS 0805-0809 (RELAY EVENT 12)
0805
0806
0807
0808
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0809
RELAY # AREA Timeout Event ID COND.
ADDRESS 0810-0814 (RELAY EVENT 13)
0810
0811
0812
0813
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0814
RELAY # AREA Timeout Event ID COND.
ADDRESS 0815-0819 (RELAY EVENT 14)
0815
0816
0817
0818
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0819
RELAY # AREA Timeout Event ID COND.
ADDRESS 0820-0824 (RELAY EVENT 15)
0820
0821
0822
0823
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0824
RELAY # AREA Timeout Event ID COND.
ADDRESS 0825-0829 (RELAY EVENT 16)
0825
0826
0827
0828
L
R
L
R
L
R
L
R
L
R
(•)
(•)
0829
RELAY # AREA Timeout Event ID COND.
RELAY EVENT OPTIONS
RELAY # AREA Timeout Event ID
L
R
L
R
L
R
L
R
L
R
(•)
(•)
COND.
Step
1
To program, follow the 5 steps below:
STEP 1:
RELAY # OPTIONS:
The GEM-P1632 supports 8 external relays
from Relay Module RM3008. Multiple events may be "mapped" to each relay,
up to a maximum of 16 events.
!
Select the relay number from
Table 1
(shown on next page); enter in
corresponding right digit address location (left digit is not used).
STEP 3:
TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
!
If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from
Table
3
(shown on next page) in minutes or seconds and enter in corresponding address location (left digit and
right digits). To choose seconds or minutes, see step 5A below. 254 is maximum entry.
Continued
Ex
ter
nal
Re
la
y C
o
ntr
o
l
STEP 4:
EVENT ID CODES:
Each relay event can be assigned any of the available event IDs from the table.
!
Select 2-digit Event ID from
Table 4
(see next page); enter in corresponding address locations (left and right digit).
STEP 5:
RELAY EVENT CONDITION OPTIONS:
Each relay event can be assigned an alarm type; and an activation
condition; also, select a timeout type for each.
!
5A. Select Alarm Type and Timeout Type from
Table 5A
(shown on next page); enter in corresponding address location (left
digit).
!
5B. Select Activation from from
Table 5B
(shown on next page); enter in corresponding address location (right digit).
[Default = blank (•) blank (•) from address 0750-0829]