16
4 TIME
:
Displays the Time for the selected Block status and Frame Numbers in HH : MM : SS : FFFF
5 Block Recording Mode : Displays Block Recording mode (Refer to Chapter 9.3.F).
S
SINGLE MODE
C
CONTINUOUS MODE
L
LOOP MODE
6 Trigger Mode
:
Display the Trigger Mode (Refer to Chapter 9.3.D).
STRT
Start Trigger Mode
CENT
Center Trigger Mode
END
End Trigger Mode
0 – 100%
Custom Trigger Mode
7 Frame Rate
:
Displays the Recording Frame Rate
8 Play Rate : Displays Playback Rate (29.97 and 59.94 or any numbers with decimal point are displayed as
integer numbers as 30 or 60).
9 Shutter Speed
:
Displays Shutter Speed. e.g. Exposure time for each frame is 1/400sec when the Frame
Rate is set 400fps and the Shutter Speed is set 100%
10 Memory Block Status
:
Displays the status of divided Blocks. The box of the current selected Block has its
color turned white.
PLAY
REC
Recorded Block
Nothing displayed
LOCK
Empty Block
11 Alert :
TEMP!!!
Appears when temperature of each part inside the camera exceeds the
TEMP LIMIT values on the HEAD MENU. When it appears, output
images and other functions of the camera can be instable. Please turn
off the power of the camera, cool it down away from direct sunlight, and
then reboot the camera.
12 Digital GAIN :
1
Displays Gain setting on the OCP when the OCP is connected to the CCU or the Camera Head.
2
When the OCP is not connected to the Camera Head (Standalone Style), display the setting of
Gain switch (0,M,H) on the right side of the camera body.
13 AWB Ch :
Summary of Contents for Hi-Moiton II
Page 5: ...5 3 Setup and Connections 3 1 OB Style ...
Page 6: ...6 3 2 Standalone Style ...
Page 14: ...14 How to unload the magnifier 1 2 3 3 4 5 6 Magnification Optics Mount Ring Cover ...
Page 26: ...26 ...
Page 65: ...65 14 2 CCU INTERCOM ...
Page 66: ...66 ...
Page 68: ...68 14 3 OCP ...
Page 69: ...69 ...
Page 70: ...70 ...