7 Adjustment
VJ-1604
Maintenance Manual
Rev.-00
7-10
5. Click [OK] to finish the setting.
CAUTION
When the plotter and PC are not directly connected with crossover cable but connected via
hub, the IP address needs to be different from that of devices on the network to be
connected. To connect via hub, consult with the network administrator.
(3) Starting Board Manager Mode
1. Connect the plotter network port and PC network port with a network cable.
NOTE
When connecting the plotter and PC on a one-to-one basis, use a "crossover cable". When connecting
the plotter and PC via hub, use a "straight cable".
NOTE
If "waiting for command" is not displayed, follow the steps below.
If IP address that is not default is displayed on the board, releasing [Back] key will display
[IP192.168.xxx.xxx] (depending on the set address) on the LCD. In this case, display either of the
default IP (IP 192.168.001.253) or the set IP address using [+] key and [-] key, and press [Enter].
Then, “Waiting for command” will be displayed.
2. When the plotter is in the operation status or in
the menu display status, press [Power] key to
turn the plotter off.
3. While holding down [Back] key in the operation
panel, press [Power] key.
The LCD displays “Board Manager Mode”. If
[Back] key is released, the display turns to
“Waiting for command”.
Summary of Contents for ValueJet VJ-1604
Page 2: ......
Page 14: ...VJ 1604 Maintenance Manual 12 ...
Page 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Page 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Page 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Page 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Page 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Page 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Page 421: ......
Page 422: ......