VJ-1604
Maintenance Manual
9 Troubleshooting
9-39
Rev.-00
6
4. Does pump motor
rotate during
cleaning operation?
•
Reconnect MAIN
board assembly
connector J22.
•
Replace pump motor.
•
Replace MAIN board
assembly.
"4.4.7
Replacing
MAIN
Board" p.4-
49
"4.2.2
Removing
Maintenance
Cover" p.4-9
5. When cleaning
operation is
performed, are gears
damaged or poorly
engaged?
Replace maintenance base
assembly.
"4.2.2
Removing
Maintenance
Cover" p.4-9
6. When cleaning
operation is
performed, is
transmission gear
shaft damaged?
Replace maintenance base
assembly.
"4.2.2
Removing
Maintenance
Cover" p.4-9
7. Does ink tube have
bend, scratch, or
leak?
•
Replace damaged ink
tube and check if
cleaning operation
causes ink inflow after
each replacement.
•
If ink inflow is
confirmed, execute
initial ink charge.
"4.7.10
Replacing
Ink Tube"
p.4-102
8. Check connection of
head cable
connectors on CR
board assembly side
and head side.
•
Is head cable inserted
obliquely?
•
Is it locked securely?
Reconnect head cable.
"4.8.9
Replacing
Print Head"
p.4-114
"4.8.3
Replacing
CR Board
Assembly"
p.4-106
Table 9-9 Symptoms, Check Items and Actions for Initial Operation Problems (Continued)
No.
Symptom
Check item
Action
Reference
Summary of Contents for ValueJet VJ-1604
Page 2: ......
Page 14: ...VJ 1604 Maintenance Manual 12 ...
Page 24: ...1 Safety Instructions VJ 1604 Maintenance Manual Rev 00 1 10 ...
Page 42: ...3 Specifications VJ 1604 Maintenance Manual Rev 00 3 8 ...
Page 198: ...4 Parts Replacement VJ 1604 Maintenance Manual Rev 00 4 156 ...
Page 266: ...5 Self Diagnosis Mode VJ 1604 Maintenance Manual Rev 00 5 68 ...
Page 404: ...10 Appendix VJ 1604 Maintenance Manual Rev 00 10 8 ...
Page 420: ...VJ 1604 Maintenance Manual Supplement Exploded View 16 ...
Page 421: ......
Page 422: ......