9 Troubleshooting
VJ-1604
Maintenance Manual
Rev.-00
9-42
11
Machine does not stop
even if front cover is
opened.
5. Check power supply
voltage (DC5V).
Replace power board
assembly.
"4.4.2
Replacing
Power Board
Assembly"
p.4-41
6. Check power supply
voltage (DC24V,
DC42V).
Replace power board
assembly.
"4.4.2
Replacing
Power Board
Assembly"
p.4-41
7. Is DC cable assembly
connected correctly
between power board
assembly and MAIN
board assembly?
•
Reconnect DC cable
assembly.
•
Replace DC cable
assembly.
"4.4.2
Replacing
Power Board
Assembly"
p.4-41
8. Main board assembly
may be defective.
Replace MAIN board
assembly.
"4.4.7
Replacing
MAIN
Board" p.4-
49
Table 9-9 Symptoms, Check Items and Actions for Initial Operation Problems (Continued)