Multiplex RX-7-DR light M-LINK Operating Instructions Manual Download Page 14

www.modellmarkt24.ch

Operating Instructions for RX-7-DR M-LINK / 

 

RX-9-DR M-LINK 2.4 GHz receivers 

MULTIPLEX Modellsport GmbH & Co.KG  •  Westliche Gewerbestraße 1  •  D-75015 Bretten (Gölshausen)  •  www.multiplex-rc.de          Page 6/6 

Ins

tr

uc

tions

 for

 R

X

-7

/9-

D

R

 M-

LIN

K

 2.

4 G

H

z r

e

ce

iv

er

s  # 985 531

9 (

10-

02-

24/M

IW

A

)  •  

E

rr

o

rs

 and om

is

si

ons

 ex

cepted! •  

¤

 MU

LT

IP

LE

X

15. CE C

ONFORMITY 

D

ECLARATION

This device has been assessed and approved in 

accordance with European harmonised directives. 
This means that you possess a product whose design and 
construction fulfil the protective aims of the European Com-

munity designed to ensure the safe operation of equipment. 
The detailed CE conformity declaration can be downloaded in 
the form of a PDF file from the Internet under www.multiplex-
rc.de. It is located in the DOWNLOADS area under PRODUKT-
INFOS. 

16. D

ISPOSAL 

N

OTES

Electrical equipment marked with the cancelled waste 
bin symbol must not be discarded in the standard 
household waste; instead it should be taken to a 

suitable specialist disposal system. 
In the countries of the EU (European Union) electrical 
equipment must not be discarded via the normal 
domestic refuse system (WEEE - Waste of Electrical and 
Electronic Equipment, Directive 2002/96/EG). You can take 
unwanted equipment to your nearest local authority waste 
collection point or recycling centre. There the equipment will be 

disposed of correctly and at no cost to you. 
By returning your unwanted equipment you can make an 
important contribution to the protection of the environment! 

17. G

UARANTEE 

/ L

IABILITY 

E

XCLUSION

The company MULTIPLEX Modellsport GmbH & Co.KG accepts 
no liability of any kind for loss, damage or costs which are due to 
the incorrect use and operation of this product, or which are 
connected with such operation in any way. Unless the law 
expressly states otherwise, the liability on the part of MULTI-
PLEX Modellsport GmbH & Co.KG to pay damages, regardless 
of the legal argument employed, is limited to the invoice value of 
those products supplied by MULTIPLEX Modellsport GmbH & 
Co.KG which were directly involved in the event in which the 
damage occurred. This does not apply if liability is incurred 
according to statutory law on account of intentional or gross 

negligence. 
We guarantee our products in accordance with the currently 
valid statutory regulations. If you wish to make a claim under 
guarantee, your initial course of action should always be to 

contact the dealer from whom you purchased the equipment. 
The guarantee does not cover faults and malfunctions which are 

caused by the following: 

x

  Incorrect or incompetent use 

x

  Maintenance carried out incorrectly, belatedly or not at all, or 

not carried out by an authorised Service Centre 

x

 Incorrect 

connections 

x

  The use of accessories other than genuine MULTIPLEX 

items 

x

  Modifications or repairs which were not carried out by 

MULTIPLEX or by an authorised MULTIPLEX Service 

Centre 

x

  Accidental or intentional damage 

x

  Defects due to normal wear and tear 

x

Operation of the unit outside the limits stated in the 

Specification

x

  Operation of the unit in conjunction with equipment made by 

other manufacturers. 

18. R

ECOMMENDED 

I

NSTALLATIONS

*Max. = As far as possible 

A

B

C

D

Í

Max.

*

Î

Í Î

Max.

*

Í

    Max.

*

    

Î

www.modellmarkt24.ch

Summary of Contents for RX-7-DR light M-LINK

Page 1: ...z D 75015 Bretten MULTIPLEX 2010 Printed in Germany www multiplex rc de Bedienungsanleitung 3 8 Operating Instructions 9 14 Notice d utilisation 15 20 Istruzioni per l uso 21 26 Instrucciones 27 32 R...

Page 2: ...www modellmarkt24 ch www modellmarkt24 ch...

Page 3: ...lesen Nur f r den vorgesehenen Einsatzbereich verwenden 4 Stromversorgung ausreichend dimensionieren 6 Einbauhinweise beachten 18 Regelm ig Reichweitentests durchf hren 13 4 EINSATZBEREICH Die 2 4 GHz...

Page 4: ...swahl erfolgt ber die Dauer des Tastendrucks 1 Fehlerz hler oder FAIL SAFE Stellungen speichern SET Taste 0 5 bis 1 Sekunde dr cken 8 8 und 8 5 2 RESET des Empf ngers auf Werkseinstellungen SET Taste...

Page 5: ...gen Daten an die Servos weitergegeben und somit der Signalverlust berbr ckt HOLD Die FAIL SAFE Einstellung bewirkt dass im St rfall die Servos nach Ablauf der HOLD Zeit in eine zuvor gesetzte Stellung...

Page 6: ...ere Spannungseinbr che unter 3 5 V bewirken einen Neustart des Empf ngers Dadurch gehen die Werte der beiden Fehlerz hler verloren Wird die SET Taste zum Zwecke der Fehlerspeicherung ge dr ckt bleiben...

Page 7: ...nbauanordnung beachten 18 Skizzen A D x Stromf hrende Kabel wie z B von Regler Motor und An triebsakku so kurz wie m glich halten x PeakFilter 8 5180 bei Einsatz von Dioden Akkuweichen verwenden x Die...

Page 8: ...r Gemeinde bzw ihres Wohnortes z B Recyclingh fen kostenlos abgeben Das Ger t wird dort f r Sie fachgerecht und kostenlos entsorgt Mit der R ckgabe Ihres Altger tes leisten Sie einen wichtigen Beitrag...

Page 9: ...only for the intended applications 4 Ensure the power supply is of adequate capacity 6 Observe the installation notes 18 Carry out regular range checks 13 4 APPLICATIONS The RX 7 DR M LINK and RX 9 DR...

Page 10: ...gth of the button press 1 Save error counter or FAIL SAFE settings Press the SET button for 0 5 to 1 second 8 8 and 8 5 2 RESET receiver to factory default settings Press the SET button for longer tha...

Page 11: ...reviously defined position at the end of the HOLD period FAIL SAFE mode ends as soon as error free signals are picked up again The factory default setting for the HOLD period is 0 75 seconds This peri...

Page 12: ...e of saving the error count the stored information is retained until the next time you save the error count 9 TELEMETRY FEEDBACK CAPABILITY The telemetry capable RX 7 DR M LINK and RX 9 DR M LINK 2 4...

Page 13: ...install a PeakFilter 8 5180 x Reception quality can be optimised by fitting a special ferrite ring 8 5146 or suppressor filter lead 8 5057 in the speed controller cable It is also advisable to fit eff...

Page 14: ...ment 17 GUARANTEE LIABILITY EXCLUSION The company MULTIPLEX Modellsport GmbH Co KG accepts no liability of any kind for loss damage or costs which are due to the incorrect use and operation of this pr...

Page 15: ...4 x Interface PC int gr e Effectuer les mises jours et les r glages avec votre PC au travers du logiciel RX DataManager 3 CONSIGNES DE SECURITES Lire attentivement les instructions avant utilisation N...

Page 16: ...e la touche SET Si vous appuyez sur la touche SET situ e sur le dessus du r cepteur lors de la mise en marche le processus de Binding se met en route 8 3 En mode r ception pour pouvez activer deux aut...

Page 17: ...0 8 1 Cause La tension d alimentation accu de r ception est trop faible R solution du probl me x Rechargez l accu de r ception ou de propulsion 8 5 HOLD et FAIL SAFE Si le r cepteur n a pas de r cepti...

Page 18: ...re les pro bl mes li s l alimentation une antenne d fectueuse etc Les erreurs de signaux sont enregistr es presque lors de chaque vol En r gle g n rale ceux ci ne se font pas remarquer mais sont d tec...

Page 19: ...e conductrice par ex fibre de carbone il faut orienter les antennes de telle mani re ce que la partie active de chacune d elles les derniers 30 mm environ se trouvent en dehors du mod le x Ne placez p...

Page 20: ...elle mais apport s au point de recyclage le plus proche Dans les pays de l union europ en EU il est stricte ment interdit de jeter ce genre d appareil lectrique avec les d chets m nag s habituels WEEE...

Page 21: ...tere in funzione leggere le istruzioni d uso Usare solo per il campo d impiego previsto 4 L alimentazione deve essere adeguata 6 Rispettare le indicazioni d installazione 18 Effettuare regolarmente de...

Page 22: ...alit di ricezione il tasto SET permette inoltre l attivazione di altre due funzioni La scelta delle funzioni avviene con la durata della pressione del tasto 1 Salvare il contatore errori o le posizion...

Page 23: ...interferenze nella ricezio ne dei dati la ricevente invia ai servi gli ultimi segnali validi ricevuti in modo da superare la perdita di segnale HOLD Con l impostazione del FAIL SAFE una volta trascors...

Page 24: ...osizione dei valori di raffronto con i quali poter riconoscere in tempo eventuali cambiamenti e le cause delle interferenze Cadute di tensione pi lunghe sotto i 3 5 V provocano il riavvio della riceve...

Page 25: ...e i cavi che sono sottoposti a correnti elevate come p es quelli del regolatore del motore o del pacco batteria x Usare il PeakFilter 8 5180 se si usano sistemi per la dop pia alimentazione x Per otti...

Page 26: ...i rici claggio dove gli apparecchi verranno smaltiti in modo idoneo e gratuito Lo smaltimento adeguato dei vecchi apparecchi elettrici aiuta a salvaguardare l ambiente 17 GARANZIA RESPONSABILIT La MUL...

Page 27: ...de datos integrado Para errores de voltaje y se al x Compatible con MULTImate 8 2094 x Interface con el PC integrada Realizaci n de ajustes y actualizaciones con el programa para PC RX DataManager 3 C...

Page 28: ...superior del receptor se pulsa al en cender dar comienzo lel proceso de asociaci n 8 3 Funcionando como receptor existen otras 2 funciones que pueden invocarse mediante la tecla SET La funci n elegid...

Page 29: ...eptor o la principal 8 5 HOLD und FAIL SAFE Cuando el receptor detecta datos interferidos o no recibe nada los ltimos datos v lidos recibidos ser n los que se entreguen a los servos y as se puentea la...

Page 30: ...fallos en una antena etc Los errores se se al se dar n en casi todos los vuelos Aunque Usted no se de cuenta de ello mientras pilota quedar n registrados por el sensor de alta sensibilidad Tras algun...

Page 31: ...os ltimos 30 mm quede fuera del modelo x No lleve las antenas por el interior del modelo o sobre con ductores P ej piezas de carbono l minas de metal pinturas metalizadas etc Se disminuir la recepci n...

Page 32: ...s pa ses de la UE Uni n Europea los disposi tivos el ctricos electr nicos no deben ser eliminados arroj ndolos en el cubo de la basura dom stica WEEE es el acr nimo de Reciclado de equipos el ctricos...

Reviews: