Flash-
ing
code
PID
SID
FMI
Description
Maintenance tasks
23
65
Oxygen concentration cir-
cuit, input voltage too high.
1. Check cabling.
2. Contact Service.
24
174
4
Fuel temperature sensor, in-
put voltage too high.
1. Check cabling.
2. Contact Service.
24
65
4
Oxygen concentration cir-
cuit, input voltage too low.
1. Check cabling.
2. Contact Service.
25
Reserved for “No Codes”.
No troubleshooting.
26
25
11
Aux. shutdown 1 active.
Contact Service.
26
61
11
Aux. shutdown 2 active.
Contact Service.
27
105
3
Inlet elbow temperature sen-
sor, input voltage too high.
1. Check cabling.
2. Contact Service.
27
171
3
Outside temperature sensor,
input voltage too high.
1. Check cabling.
2. Contact Service.
27
172
3
Air temperature sensor, in-
put voltage too high.
1. Check cabling.
2. Contact Service.
28
105
4
Inlet elbow temperature sen-
sor, input voltage too low.
1. Check cabling.
2. Contact Service.
28
171
4
Outside temperature sensor,
input voltage too low.
1. Check cabling.
2. Contact Service.
28
172
4
Air temperature sensor, in-
put voltage too low.
1. Check cabling.
2. Contact Service.
29
351
4
Circuit exhaust turbocharger
inlet temperature defective /
low (version 33.0 or later).
1. Check cabling.
2. Contact Service.
29
404
4
Temperature sensor/ ex-
haust turbocharger outlet, in-
put voltage too low (version
32.0 or later).
1. Check cabling.
2. Contact Service.
31
51
3
Auxiliary output 3, open cir-
cuit (side "high") S3.
Contact Service.
31
51
4
Auxiliary output 3, ground
short circuit (side "high") S3.
Contact Service.
31
51
7
Auxiliary output 3, fault in
mechanical system S3.
Contact Service.
31
52
3
Auxiliary output 4, open cir-
cuit (side "high") S3.
Contact Service.
31
52
4
Auxiliary output 4, ground
short circuit (side "high") T3.
Contact Service.
31
52
7
Auxiliary output 4, fault in
mechanical system T3.
Contact Service.
32
238
3
SEL, short circuit on battery
circuit (plus).
1. Check cabling.
2. Contact Service.
32
238
4
SEL, open circuit .
1. Check cabling.
2. Contact Service.
32
239
3
CEL, short circuit on battery
circuit (plus).
1. Check cabling.
2. Contact Service.
MS150049/04E 2017-04
| Troubleshooting | 59
TIM-ID: 0000003162 - 002