8.11.2 Cold start system with ether injection – Check
Preconditions
☑
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Ether cartridge
(→ Spare Parts Catalog)
DANGER
Cleaner is an explosive and poisonous substance.
Danger to life, major material damage!
• Avoid open flames, electrical sparks and ignition sources.
• Wear goggles/facial protection.
• Only work in a well-ventilated room.
• Do not smoke.
Checking filling level and condi-
tion of system
Note:
After two successive starting attempts with
cold start system, try to start the engine
again after 10 minutes only. If the next two
staring trials fail, contact Service.
1.
If the indicator lamp on the relay module (5)
lights up, fit a new ether cartridge (1).
2.
Check the condition of lines (2) and connec-
tions. If damage is found, contact Service.
3.
Check the condition of electric lines (4) and
connections. If damage is found, contact
Service.
4.
If the system fails, check fuses in fuse holder
(3). If fuses are broken, contact Service.
106 | Starting Equipment | MS150049/04E 2017-04