8.8 Fuel System
8.8.1 Fuel system – Venting
Preconditions
☑
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Filling device
B80144852
1
Diesel fuel
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
• Avoid open flames, electrical sparks and ignition sources.
• Do not smoke.
• Wear protective clothing, protective gloves, and safety glasses / facial protection.
LP fuel system – Venting
1.
Connect filling device to connection (4).
2.
Disconnect return line at connection (1).
3.
Use hand pump to fill fuel system, providing
pressure of min. 0.5 bar / max. 2.0 bar, until
fuel emerges without bubbles at connec-
tion (1).
4.
Connect return line to connection (1).
5.
Open vent plug (2) on filter housing (3).
6.
Use hand pump to fill fuel system, providing
pressure of min. 0.5 bar / max. 2.0 bar, until
fuel emerges without bubbles at connec-
tion (2).
7.
Close vent plug (2).
8.
Remove filling device and seal connection (4).
102 | Fuel System | MS150049/04E 2017-04
TIM-ID: 0000004708 - 004