5.5 Engine – Stopping in manual mode
Preconditions
☑
Engine is not under load.
☑
Engine is running in manual mode.
NOTICE
Stopping the engine when it is running at full load subjects it to extreme thermal and mechanical stress-
es.
Overheating of and, therefore, damage to components is possible!
• Before shutting down the engine, allow it to idle until the engine temperatures decrease and constant
levels are indicated.
Preparation
Item
Measure
Engine
Operate engine at idling speed for approx. 5 minutes.
Stop engine
Item
Measure
Switch cabinet, operator
station etc. (depending on
manufacturer)
Press stop button.
• Automatic stopping sequence is executed.
MS150049/04E 2017-04
| Operation | 49
TIM-ID: 0000002291 - 005