Fault code No. Full designation
Meaning
Action
Related
parameter
No.
476
AL Crash Rec. Init. Error
Alarm configuration; Initiali-
zation error of crash record-
er.
Check settings with
DiaSys.
1.8010.00
7
478
AL Comb. Alarm Yellow
(Plant)
Alarm configuration; Com-
bined alarm YELLOW from
plant.
Note further fault
messages.
2.8006.00
1
479
AL Comb. Alarm Red
(Plant)
Alarm configuration; Com-
bined alarm RED from plant.
Note further fault
messages.
2.8006.00
2
480
AL Lim Ext. Plant Bin
Alarm configuration limit val-
ue; input signal has exceed-
ed / not attained limit, de-
pending on configuration.
Determine cause of
limit value violation
and rectify fault.
2.0291.92
1
M015695/03E 2013-03
| Troubleshooting | 77
TIM-ID: 0000033662 - 001