Safety
Senscient ELDS™
Rev 15
3
GB
Safety
Ensure that you read and understand these instructions
BEFORE
operating the equipment.
Please pay particular attention to the safety Warnings / Special Conditions of Safe Use.
Warnings / Special Conditions of Safe Use
WARNING
1. The Senscient ELDS™ 1000 / 2000 Series gas detectors are Baseefa ATEX certified for use
in Hazardous (Explosive) Atmospheres; and CSA(UL) certified for use in Hazardous
(Classified) Locations/Zones.
2. For installations in Europe (ATEX Certified) install in accordance with IEC/EN60079-14.
3. For installations in North America and Canada install in accordance with ANSI/NFPA 70, the
Canadian Electrical Code C22.1 and the manufacturer’s instructions.
4. Elsewhere, the appropriate local or national regulations should be used.
5. ELDS™ 1000 / 2000 Series gas detectors must be properly earthed / grounded to protect
against electrical shock and minimise electrical interference. Internal and external
equipotential bonding facilities are provided for this purpose. For electrical installation design
considerations refer to section 3.3.
6. Operators must be fully aware of the action to be taken if the gas concentration exceeds an
alarm level.
7. ELDS 1000 / 2000 Series gas detectors do not contain any parts that can be replaced or
repaired by customers. If units require repair they must be safely removed from any
hazardous location / area in which they are installed, and returned to Senscient. Other than
the rear cover providing access to the terminals for connection purposes, the units are not
intended to be opened during operational service.
8. Test gases may be toxic and/or combustible. Refer to Material Safety Data Sheets for
appropriate warnings and handling procedures / precautions.
9. Do not drill holes in any housing as this will invalidate the explosion-proof protection.
10. In order to maintain electrical safety, units must not be operated in atmospheres with more
than 21% v/v oxygen.
11. Ensure that the bolts which secure the front flameproof enclosure are fully tightened. The
securing bolts are stainless steel M5 X 16mm socket head cap screws grade A4-70. To
ensure replacement suitability contact Senscient or their approved agent/distributor.
12. Do not open the enclosure in the presence of an explosive atmosphere. Keep cover tight
when energised
13. The apparatus is certified for use in Hazardous Areas at atmospheric pressures not
exceeding 1.1 bar (16 psi).
14. Install only in environments with ambient temperature ranges of -40°C to +60°C.
15. For Europe (ATEX), apparatus incorporates an integral threaded cable entry (M25 x 1.5).
Terminate cable only with a suitable equipment certified ATEX cable gland (not a
component). To maintain water and dust ingress protection seal threads with suitable non-
hardening sealant as described in IEC/EN 60079-14.
Note:
See control drawing for product specification allowing selection of cable glands.
Summary of Contents for Senscient ELDS 1000 series
Page 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Page 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Page 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Page 159: ...Appendix D Manufacturer s EC Declarations Senscient ELDS Rev 15 159 GB ...
Page 160: ...Appendix D Manufacturer s EC Declarations 160 Senscient ELDS Rev 15 GB ...
Page 184: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose ...