![MSA Senscient ELDS 1000 series Operating Manual Download Page 178](http://html.mh-extra.com/html/msa/senscient-elds-1000-series/senscient-elds-1000-series_operating-manual_1846249178.webp)
Appendix G – Measurement Range Guidelines
178
Senscient ELDS™
Rev 15
GB
Guideline Measurement Ranges and Alarm Thresholds for ELDS Open Path HCl Detectors
Application ►
Health / Environmental
Path Length
5-30 m
R 0-50ppm.m
A1: 15ppm.m
A2: 25ppm.m
Path Length
30-60 m
R 0-50ppm.m
A1: 20ppm.m
A2: 30ppm.m
Path Length
60-90 m
R 0-50ppm.m
A1: 30ppm.m
A2: 40ppm.m
Path Length
90-120 m
R 0-50ppm.m
A1: 30ppm.m
A2: 40ppm.m
Guideline Measurement Ranges and Alarm Thresholds for ELDS Open Path Carbon Dioxide
(CO
2
) Detectors
Application ►
Leak Hazard Detection
Path Length
5-30 m
R 0-300,000ppm.m
A1: 60,000ppm.m
A2: 120,000ppm.m
Path Length
30-60 m
R 0-300,000ppm.m
A1: 60,000ppm.m
A2: 120,000ppm.m
Path Length
60-90 m
R 0-300,000ppm.m
A1: 120,000ppm.m
A2: 180,000ppm.m
Path Length
90-120 m
R 0-300,000ppm.m
A1:180,000ppm.m
A2: 240,000ppm.m
Summary of Contents for Senscient ELDS 1000 series
Page 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Page 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Page 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Page 159: ...Appendix D Manufacturer s EC Declarations Senscient ELDS Rev 15 159 GB ...
Page 160: ...Appendix D Manufacturer s EC Declarations 160 Senscient ELDS Rev 15 GB ...
Page 184: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose ...