There will be some installations and physical environments in which it is very difficult or
even impossible to establish reliable Bluetooth™ communications. Senscient cannot
guarantee reliable Bluetooth™ communications in every installation or environment.
Failure to achieve reliable Bluetooth™ communications with a particular ELDS unit does
not mean that the ELDS unit is faulty. If it is not possible to use Bluetooth™ in a particular
instance, check that power is reaching the ELDS unit and use the hard-wired RS485
communications link to perform any necessary actions.
4.7. Installation Checklist
The following information is for the guidance of personnel carrying out installation checks / tests on
Senscient ELDS™ OPGDs. In general it should be noted that:
Installation of ELDS™ 1000 / 2000 Series OPGDs should be performed by personnel trained by
Senscient or authorised trainers.
Detailed information concerning installation, alignment and commissioning is provided in this
Technical Manual.
Senscient ELDS™ is explosion protected by a certified, explosion-proof enclosure. Carefully read
the safety warnings, cautions and certification details in this manual. Ensure that they have been
complied with, before and during the installation.
The following is a check list with notes to assist the installer:
Operating Range
Check the distance (preferably in metres), between the Transmitter and the Receiver.
Is the unit being installed suitable for this operating range?
Detector Location
Check the location / position of the unit, e.g.
West Walkway, Compressor Skid
Is this the correct location / position for the unit?
Tag No
Check the Tag No, or equivalent, that has been allocated to the ELDS™ Receiver and
Transmitter units. Do the Tag No.’s and details for the units all tie up?
Mod State
Check the Mod State of the units as indicated on their certification labels.
Certification
Check the certification of the units, e.g.
Baseefa ATEX/IECEx (Europe),
Is the Hazardous Area Certification of the unit correct for the Hazardous Area/Zone where it is
being installed?
Summary of Contents for Senscient ELDS 1000 series
Page 58: ...Installation Commissioning 58 Senscient ELDS Rev 15 GB 2 x Mounting Brackets ...
Page 140: ...Certification 140 Senscient ELDS Rev 15 GB 9 1 2 Control Drawing CENELEC ATEX ...
Page 142: ...Certification 142 Senscient ELDS Rev 15 GB 9 1 4 Control Drawing CSA US Canada ...
Page 159: ...Appendix D Manufacturer s EC Declarations Senscient ELDS Rev 15 159 GB ...
Page 160: ...Appendix D Manufacturer s EC Declarations 160 Senscient ELDS Rev 15 GB ...
Page 184: ...For local MSA contacts please visit us at MSAsafety com Because every life has a purpose ...