78
Certification
GB
G1 Integrated SCBA System
18
Certification
18.1 Complete Device
18.2 Marking for the SCBA G1
Ensure that the device is not submitted to temperatures that exceed those permitted for any part
of equipment used together with the device.
Full face mask
: see operating manual for Full Face Mask and Mask/Helmet Combination.
The ATEX class of any other equipment used together with this device has to be regarded as well.
The lowest class sets the limit.
The Declaration of Conformity can be found under the following link: https://MSAsafety.com/DoC
Approvals
The compressed air breathing apparatus conforms to the Directive
89/686/EC or Regulation
(EU)
2016/425, respectively, and
Directive
2014/34/EU. It is a self-contained open circuit compressed air
breathing apparatus in accordance with EN 137:2006, type 2.
The function of the electronic components were not assessed for the certi-
fication in accordance with Directive 89/686/EC or Regulation
(EU)
2016/
425, because even in case of a complete failure of all electronic
compo-nents, the respiratory protection provided by MSA G1 remains
unchanged.
0158
DEKRA
DEKRA Testing and Certification GmbH,
Dinnendahlstr. 9,
44809 Bochum, Germany
BVS 15 ATEX H 010 X
Pneumatic (P)
II 3G IIB TX
II 3D TX
-40 °C
T
a
+60 °C
Electronic (E)
II 3G IIB TX
-30 °C
T
a
+60 °C
TX: The permissible surface temperature depends on device configuration. The permissible
surface temperature of any other equipment used together with this SCBA has to be regarded as