Buddy Breather
GB
G1 Integrated SCBA System
a) Position the manifold end of the hose toward the flap opening to ensure that it is accessible
in an emergency breathing situation.
Pouch
(1) Inspect the pouch for cuts, tears, abrasions or signs of damage due to heat or chemical expo-
sure.
a) Verify that the pouch can securely stow and protect the emergency breathing hose.
b) Verify that the pouch is securely attached to the carrier and harness.
(2) Verify that each snap on the pouch flap is in place and securely fastened.
Hose Restraint
(1) Inspect the hose restraint for cuts, tears, abrasions or damage due to heat or chemical expo-
sure.
(2) Verify that the hose restraint is securely attached to the emergency breathing hose and to
the backplate.
17.3 Preparation for Use
Before Entering a Toxic Environment
(1) Ensure proper Buddy Breather connection to the first stage regulator, as described in the
inspection before use.
(2) Don the apparatus as described in the donning section.
17.4 Providing or Obtaining Emergency Breathing Support
WARNING!
Follow these procedures to connect and disconnect the emergency breathing system hardware.
Individual development of operating procedures and sufficient training is required to use this
equipment in actual emergency conditions. Misuse can result in serious injury or death.