82
Certification
GB
G1 Integrated SCBA System
18.4 Australia
The LRR frequency for Australia is 915 - 928 MHz.
Special conditions for safe use:
• Properly donning and doffing of the self-contained breathing apparatus shall be done only in
non-hazardous areas.
• Before entering the hazardous area, the complete self contained breathing apparatus elec-
tronics type G1 has to be checked for mechanical damages including the conductive ink layers
of the housings.
• The disconnection of the alkaline battery pack and the changing of the batteries is only allowed
in non hazardous area.
• Replace only batteries of the same type
• -The maximum RF radiation power of the antenna used for activation of the RFID Tag type
LOGI TAGTM 161 HF in hazardous areas shall not exceeded 2W for Group IIC.
• The ambient temperature range is - 30 °C
≤
Ta
≤
+ 60 °C .
Quality Assurance Notification: 0080
Year of Manufacture:
see Label
Serial No.:
see Label