Control Module (ADSU) (Version with Integrated Electronics only)
GB
G1 Integrated SCBA System
9.3
Secondary Alarms
The buddy light status remains based on pressure status for secondary alarms.
9.4
Thermal Alarm
WARNING!
Although the thermal alarm provides an indication that the temperature/time curve is exceeded,
because of variations in individuals and protective clothing, the curve may not represent the
threshold to injury accurately. Use the thermal alarm only as a reference to increasing tempera-
ture/time. Do not use the thermal alarm as a substitute for standard operating procedures for
escape from temperature/time extremes.
Failure to obey this warning can result in serious personal injury or death.
If the option for the thermal alarm is activated, the control module monitors thermal conditions.
The thermal alarm can be set as a primary or secondary (default) alarm. If the user is exposed to
more than the preset limit of thermal load (temperature/time), the secondary alarm shows on the
control module and the power module emits a tone every 5 seconds.
The following figure shows the thermal alarm activation curve for the control module. The
temperature/time limits correspond to this graph. The thermal alarm activates if the preset limit
exceeds the curve shown on the graph. Depending on the severity of conditions, the alarm will
self-cancel. This may occur even though the temperature is above the thermal curve.
Thermal Alarm
Confirm
(Primary)
Red Attention
Solid
Red
None
LCD Temp
Alarm
Blue Atten-
tion Flashing
Based on
Pressure
None
Low Battery
Yellow Battery
Flashing
Based on
Pressure
Beep every
10 seconds
Medium Pres-
sure Alarm
None
Yellow
Optional sound (See
alphaCONTROL 2
Software)
Alarm Type
HUD
Control
Module
Buddy Lights
Sound
Icon
The attention icon flashes for an active and new warning or is steady for an old/ seen
warnings that have been viewed.
Evacuation alarm, the running man icon is visible on the primary screen if the evacuation
has been confirmed.