PE-05 N95 RESPIRATOR DATASHEET/ USER INSTRUCTION 

 

 

 

 

 

 

 

 

 

Date: 

01/07/22 

Document Number: PP004 

Revision: 

E

 

 

 

Product name: N95 Particulate Respirator 

Model Number: PE-05 

Part Number: PE-05 S (small size head strap length); PE-05 L (large size head strap length) 

Product description

: N95-Particulate Respirator (filter efficiency level of 95% or greater against 

particulate  aerosols  free  of  oil).  Time  use  restrictions  may  apply.  This  product  contains  no 
components made from natural rubber latex. This respirator is disposable and non-sterile. 

Important

:  

This respirator helps protect against certain particles. 

Misuse may result in sickness or death

. For 

correct use, consult your supervisor and these user instructions. 

Before use, wearer must read and understand these user instructions. Keep these instructions for 
reference. 

For more information and assistance including technical support, contact us at: 
Phenotype Pharmaceuticals   

 

Email: [email protected]  

1255 Park Ave, Suite A 

 

 

Phone: 510-817-4008 

Emeryville, CA 94608 

 

Fitting Instructions: 

Follow these instructions each time a respirator is worn

Clean your hands with soap and water or hand sanitizer before touching the respirator. 

Remove a respirator from the package, unfold it and make sure there are no obvious tears or holes 
in either side of the respirator or on head straps. 

Orient  the  respirator  with  the  Nose  Strip  pointing  up.  The  side  of  the  respirator  that  has  a  stiff 
bendable edge is the top and is meant to mold to the shape of your nose. 

Hold the respirator against your face (covering  nose, mouth and chin) with one hand, and using 
your other hand, position top head strap over the top of your head, above the ears. 

For the bottom head strap, use one hand to press against the attachment points where the strap is 
connected to the respirator body, and use the other hand to pull the bottom strap over your head to 
your neck area, below your ears. 

Make sure the respirator covers your nose and wraps under your chin with the nose piece up.  

Using the fingers of both hands, bend the metal nose clip around your nose to form a tight seal. 

Using only one hand to mold the nose piece may cause an improper fit.

 

Perform a fit check. Place both hands over the respirator. Exhale sharply to check for air leaks. 

If air leaks at the respirator edges, re-adjust position of the two head straps along the sides of your 
head until maximum fit and seal is  achieved.  If  air leaks around nose re-adjust the nosepiece  as 
described. 