65
Maintenance and Care of the SCBA
GB
G1 Integrated SCBA System
13.5.1 Rechargeable Battery Module
WARNING!
Do not use a rechargeable battery module which shows signs of damage, such as bulging,
swelling, leaking fluid, a cracked housing, or damaged contacts. Failure to follow this warning can
result in a loss of electronics functionality and serious personal injury or death.
WARNING!
Use only battery charger MSA 10170546 with rechargeable battery module MSA 10161002. Do
not remove or install the rechargeable battery module in an environment with explosive concen-
trations of combustible gases, vapors, or mists. Failure to follow this warning will void Intrinsic
Safety approval and may result in an explosion or fire.
CAUTION!
Recharge the rechargeable battery module if the low battery alarm has activated. Failure to follow
this warning may result in a loss of electronics functionality during subsequent product use.
CAUTION!
Do not use force to remove or replace the rechargeable battery module. Do not attempt to open
the rechargeable battery module housing. The rechargeable battery module does not contain
replaceable cells.
Only use the battery charger indoors.
Do not charge a rechargeable battery module in temperatures below 0 °C or above 40 °C. Do
not use a damaged battery charger. Replace the charger if the cord is damaged or worn, or if
the case is cracked or distorted.
Failure to follow these warnings may result in damage and inoperability of the battery module
and power module.
CAUTION!
Do not attempt to charge alkaline battery modules with the charger. Failure to follow this warning
may result in damage to the battery charger.
(11) Insert the battery pack into the power module, ensure to align
it with the grooves in the power module.
a) Release the battery module and push in its top.
b) The battery module will click into place.
(12) To make sure that the battery pack fits securely, push on the
opposite side of the power module, the battery pack should
not move.
(1) Place the charger horizontally on a flat surface and in a dust-
free area with a temperature range between 0°C and 40°C.
The ideal temperature is 21°C.