41
Control Module (ADSU) (Version with Integrated Electronics only)
GB
G1 Integrated SCBA System
9.2
Primary Alarms
Below is the list of alarms the alarm and control device is capable of indicating to the user.
Optional alarms can be activated by using the MSA alphaCONTROL 2 Software.
Alarm Type
HUD
Control
Module
Buddy Lights
Sound
Motion pre-
alarm
Red Attention
Flashing
Red Pre-alarm
Motion/manual
full alarm
Red Attention
Solid
Red Full
Alarm
Low pressure
alarm
Red Pressure
Flashing
Red
Optional sound (See
alphaCONTROL 2
Software)
Pressure drop
alarm
(optional)
Blue Atten-
tion Flashing
Red
Optional sound (See
alphaCONTROL 2
Software)
Evacuate
(if equipped)
Red Evacua-
tion Flashing
Red Sweep
Evacuation
confirmed(if
equipped)
Red Evacua-
tion Solid
Red None
Hardware
failure
Red Attention
Flashing
Red Full
Alarm
Thermal Alarm
Primary
(optional)
Red Attention
Flashing
Red
Optional sound (See
alphaCONTROL 2
Software)
Thermal Alarm
Secondary
(optional)
Blue Atten-
tion Flashing
Based on
pressure
Optional sound (See
alphaCONTROL 2
Software)