NOTE:
This chart was generated from data obtained in a laboratory setting and is for reference
only. Conditions are highly variable in an actual-use scenario. Users of the thermal alarm option
should develop procedures for the use of this feature.
9.5
Secondary Alarm Icons
The secondary alarm icon indicates either the thermal alarm, battery alarm, or radio connection
loss occurred. These icons will remain on the main screen until the condition is corrected by the
system (example: radio connection is re-established).
The evacuate alarm can be cleared by restarting the SCBA or by receiving the "rest evacuation
alarm" message from alphaCONTROL.
Secondary Screen
The secondary screen provides the user information if needed by the user. To switch to the
secondary screen, press the RESET button once.
The secondary screen displays
• temperature icon
• short range radio icon
• long range radio icon (only with telemetry option)
• battery icon
• time remaining calculation
Similar to the primary screen, the time remaining calculation is configurable to pressure status,
time remaining or breathing time.
The icons on the screen indicate different states of the device. The chart below explains the
different states of the device.