24
Functional Tests
GB
G1 Integrated SCBA System
5.6
Control Module, Power Module, HUD, and Primary Low-Pressure Warning Device Opera-
tion
When testing the control module, lay the control module down flat to check the white light illumi-
nating the pressure gauge and to check if the graphical display and the analog gauge match within
a 10 bar range.
Manual alarm can be reset using the green buttons on the control module.
Verify proper function of the HUD, control module, power module, and low pressure warning
device by observing the control module gauge and display when the alarms sound. Perform this
test with a full cylinder.
(1) Pressurize the system by opening the cylinder valve.
a) Observe the starting sequence of the LEDs on the LGDV.
b) Listen for the power module to sound and for the primary low pressure warning alarm to
sound briefly.
c) Ensure that the buddy lights are flashing green.
d) Ensure the pressure gauge and LCD display (if configured) show the correct pressure.
(2) Allow the control module to remain motionless for approximately 20 seconds.
a) Listen for the power module to sound repeated tones of the pre-alarm.
b) Verify that the buddy lights are flashing red.
c) Verify that the red LED is flashing in the HUD.
(3) Shake the control module to reset the alarm before the unit goes into full alarm.
(4) Allow the control module to remain motionless until the full alarm sounds (30 seconds).
a) Listen for the power module to sound the tones of the full alarm.
b) Verify that the buddy lights are flashing red.
c) Verify that the red LED is displayed in the HUD.
d) Verify that shaking the control module does not reset the full alarm.
(5) Reset the motion alarm by pressing the left reset button (green) on the side of the control
module twice within approximately one second.