5 Mounting
38
TAPCON® 230 basic
2117246/02 EN
© Maschinenfabrik Reinhausen 2012
5.3
Mounting device
After unpacking, mounting can begin.
Mounting requires the Allen key, wrench 3 supplied. This is delivered along
with the door key in a plastic bag attached to the inside of the inspection win-
dow on the swing door.
The following installation/mounting variants are possible:
Flush panel mounting(page 40)
Wall mounting (page 42)
Wall mounting with flat-bar mounting bracket (page 44)
Cap rail mounting (optional) (page 45)
These variants are described below.
5.3.1
Preparing for mounting
Before commencing mounting, the two fixing brackets back on the rear of the
device must be removed and the M screw connection plate taken off. To do
so, proceed as follows:
1. Unscrew the 4 hexagon socket screws on the pre-mounted fixing brackets
with the Allen key provided.
2. Take off both fixing brackets.
3. Unscrew the 4 hexagon socket screws on the M screw connection plate
using the Allen key provided.
4. Remove the M screw connection plate.