Restoring, resetting and rebooting
Chapter 7 Operation
phn-2182_002v000
7-28
May 2011
Recovering a lost IP address
To recover a lost IP address, physical access to the PoE power supply is recommended.
NOTE
The unit does still respond to its normal IP address through a power cycle.
If the IP address of the unit has been lost or forgotten, proceed as follows:
1
Set the management PC Ethernet port to an IP address that is valid for
the 169.254.X.X network, avoiding 169.254.0.0, 169.254.1.1 and
169.254.1.2. Refer to
Configuring the management PC
on page
6-3
.
2
Connect the management PC Ethernet port to the DATA IN port of the
PoE power supply using a standard (not crossed) Cat5e cable (
Figure
6-3
).
3
Perform a power cycle, that is, disconnect and then reconnect the PoE
power supply to its AC supply.
4
Access the web interface within 30 seconds of powering on, using default
IP address 169.254.1.1.
5
Select menu option
Configuration, LAN Configuration
.
6
Obtain the correct IP address of the unit from the LAN Configuration
page.
Rebooting the unit
To reboot the ODU select menu option
Reboot PTP 250
. The Reboot Wireless Unit
page is displayed (
Figure 7-14
). Select
Reboot PTP 250
to confirm
.
Figure 7-14
Reboot Wireless Unit page
Summary of Contents for Motorola PTP 250
Page 20: ...List of Tables phn 2182_002v000 xiv May 2011 ...
Page 30: ......
Page 80: ...Data network planning Chapter 2 Planning considerations phn 2182_002v000 2 22 May 2011 ...
Page 126: ...Notifications Chapter 4 Reference information phn 2182_002v000 4 36 May 2011 ...
Page 234: ...Testing the radio link Chapter 8 Troubleshooting phn 2182_002v000 8 14 May 2011 ...