May 2018
±100mA
TX Power Supply:
Open Circuit
Voltage/Short-Circuit Current:
25.2V/42.5mA, Available
Voltage: 17V @ 23.6mA
Relay Outputs:
Single-pole/
double-throw (SPDT), 1 form C,
rated 5A@250Vac, 50/60Hz or
24Vdc, non-inductive
WITH ANALOG OUTPUT
Output Accuracy:
Current,
±0.01% of max. span (±2
microamps); Voltage, ±0.01% of
maximum span (±1mV)
Response Time:
256msec
maximum (128msec typical) for
the output to change from 10%
to 90% of its scale for an input
step change of 0 to 100%
Ripple (up to 120Hz):
Current output 10mVp-p when
measured across a 250ohm
resistor; Voltage output,
50mVp-p maximum
Output Limiting:
Load Capability:
Source mode
(internal power supply), 0-1000
ohms
Load Effect:
±0.01% of span
from 0 to 1000 ohms
Operating Range:
-40°C to +85°C
(-40°F to +185°F)
Storage Range:
-40°C to +85°C
(-40°F to +185°F)
Ambient Temperature Effect:
Input: Current, 2 microamps/°C;
Voltage, 1mV/°C; Output:
±0.009% of max. span/°C
Section 7:
Specifications
SPA
2
HLPRG Specifications
Input Range:
Current Input
0-50mA (1mA minimum
span); Voltage Input 0-11V
(250mV minimum)
Input Accuracy and Alarm
Trip Repeatability:
Current
inputs, ±2 microamps (0.01%
of 20mA span); Voltage
inputs, ±1mV (0.01% of max.
span)
Stability:
Refer to
Table 1 (Table 7.1 section 7
of manual)
Dead Band:
11.5V or 50mA,
maximum in Linear Mode;
equivalent of maximum input
range in user-set engineering
units in Scaling/Custom
Mode
Response Time:
256msec
typical (Defined as the time
from step change on input
to alarm state change when
alarm is set to trip at
mid-point)
Alarm Trip Delay:
Programmable from 0-120
seconds
Power Supply Effect:
±0.002% of span for a
1% change in line voltage
(AC or DC)
Isolation:
500Vrms between
case, input, output (units
with -AO option) and power,
continuous.
Dielectric Strength:
Will
withstand 1560Vrms for 2
seconds between input,
output and power; 500Vrms
for 2 seconds from case to
input, output or power
Power Supply:
Universal 21.6-125Vdc or
90-260Vac;
Power Consumption:
3.5W typical, 5.5W maximum
Input Impedance:
Current
inputs, 20ohms; Voltage
inputs, 1Mohm
Input Over-Range
Protection:
Voltage inputs,
±30Vdc; Current inputs,
Performance
Performance
(continued)
Ambient
Conditions
(continued)
Adjustments
Weight
Relative Humidity:
5-95% non-condensing
RFI/EMI Protection:
80% AM at 1Khz 20V/m
@ 20-1000Mhz per
IEC61000-4-3.
Noise Rejection:
Common Mode,
100dB@50/60Hz
Normal Mode,
Current Input, 70dB
typical@50mAp-p@
50/60Hz; Voltage Input,
70dB typical@1Vp-p@
50/60Hz
Front panel pushbuttons
parameter configurations;
Internal jumper and
menu password protect
parameter settings
LCD:
2x5 14-segment
characters, backlit,
alphanumeric readout
accurate to the nearest
digit.
Range:
-99999 to 99999;
Decimal point can be
user-set
LED Type:
INPUT LED:
Dual color LED indicates
input failure
READY LED: Green LED
indicates unit is operating
properly
ALARM 1, 2, 3 and 4 LED:
Dual color LED per relay
indicates alarm status
Display Accuracy:
±1
digit; when scaling the
display (or in Custom
Mode), high input-to-
display span ratios
decrease display accuracy
544 g to 618 g
(19.2 oz to 21.8 oz)
Ambient
Conditions
Indicators
Performance
with Analog
Output (-AO
Option)
Specifications and information subject to change without notice.
0-20mA 0, 23.6mA
4-20mA 3.6, 23.6mA
X-20mA
(0<X<4)
Output
Failure Limits
(90% of X), 23.6mA
Programmable Limit Alarm Trips