Fusion Compact Pro Bread Plant, Rev. A21 14-04-21
54
9.0 MAINTENANCE
ISOLATE DIVIDER FROM MAINS SUPPLY BEFORE ATTEMPTING ANY
MAINTENANCE OPERATIONS.
MAINTENANCE SHOULD ONLY BE CARRIED OUT BY FULLY TRAINED
PERSONNEL.
Due to the low maintenance design of the divider, maintenance consists of the operations
in the cleaning section and a few of the following checks:
Conveyor belt adjustment (as required).
Condition and greasing (check monthly)
Weight adjuster chain condition and greasing (check monthly)
Conveyor Belt Adjustment
Conveyor belt should be no tighter than necessary to eliminate slippage.
Over tensioning can lead to belt and/or bearing failure.
The belt should be adjusted by means of the adjustment tensioning nuts.
The belt should run with equal clearance between its edges and the conveyor unit side
frames. If one edge of the belt is tighter than the other, it will tend to run towards the slack
side. This tracking defect can be eliminated by individual adjustment of the tensioning
nuts.
Caution
Adjustment nuts should not be continually tightened (this will cause bearing failure or the
moulding belt to stretch and break). It may be that one side is too tight so should be eased
off a little.
ADJUSTMENT NUTS
(each side)
Summary of Contents for Fusion Compact PRO
Page 4: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 2...
Page 10: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 8 BREADPLANT ASSEMBLED SECTION 1...
Page 60: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 58...
Page 61: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 59...
Page 62: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 60...
Page 63: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 61...
Page 64: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 62 YASKAWA INVERTER DEFAULT SETTINGS...
Page 67: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 65 ELECTRICAL DISTRIBUTION...
Page 68: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 66 CONTROL CIRCUIT...
Page 87: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 85...
Page 88: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 86 11 0 ELECTRICAL INFORMATION...
Page 89: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 87...
Page 90: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 88...
Page 102: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 100 11 0 ELECTRICAL INFORMATION...
Page 103: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 101...
Page 104: ...Fusion Compact Pro Bread Plant Rev A21 14 04 21 102...
Page 105: ......