Engine Heat Exchange System:
When traveling, the water pump on the engine
circulates heated engine coolant through the
Hydro-Hot. Through convection, heat transfers
to the Hydro-Hot coolant, providing hot water
and interior heating. Use the Comfort Control to
operate the heat exchangers.
To Heat the Interior While Traveling:
Turn
ON
the
interior house
power.
Set the Comfort
Controls to
Furnace.
Select the
desired Zone and
Temperature.
Troubleshooting
An electronic display panel (Electronic
Controller) is located next to the Hydro-Hot in
the curbside bay. The display panel has LED
fault indicators that are used for diagnostics. If a
heating source is selected (diesel or electric) and
the Hydro-Hot does not appear to be working,
check to see if any LED fault indicators are lit
on the electronic display panel. A fault lamp
may be overlooked due to viewing angle.
Low Tank Level Cutoff:
Heating
function has shutdown due to low level
of coolant in the Hydro-Hot. Check
coolant level.
Electric Heating Element Status:
Green indicator means the Hydro-Hot is
being heated by 120 Volts AC.
Low Voltage Reset:
The Low Battery
Voltage Fault LED will illuminate. Reset
the Controller by cycling the Diesel
burner switch or inserting a paperclip
into the hole. Press the reset button.
Heating Status:
The Hydro-Hot is being
heated by Diesel or the 120 Volt AC
electric element.
Heating Zones Status:
A thermostat is
calling for heat in a zone. Normal LED
is green. Red LED means a short has
occurred in that zone.
Pump Status:
When a pump is
operating, LED is green. A red LED
indicates a short in the pump.
Low Battery Voltage Fault:
Red
LED indicates that battery voltage is
low. Hook to shore power or start the
generator. The Hydro-Hot will not
function until the Electronic Controller
is reset by cycling the Diesel Burner
switch off then back to on, or by
inserting a paperclip or similar tool into
the Low Voltage Reset hole. Press the
Reset button.
Bay Thermostat
During cold weather, a thermostat in the
holding tank compartment will turn on the
exchanger in the storage bay to prevent freezing.
The thermostat turns on at 45º F +/- 10º. Ensure
the Hydro-Hot is
ON
to heat the bay.
NOTE:
Turn the Hydro-Hot ON when heating
the bay.
050200h
030983
Bay Thermostat
040486c
Electronic
Controller
04086b
Summary of Contents for Camelot 2007
Page 16: ......
Page 18: ......
Page 49: ...45 Section 2 Driving Safety Camelot 2007 Weight Record Sheet Actual Worksheet 020255b...
Page 53: ...49 Section 2 Driving Safety Camelot 2007 Weighing Procedure Worksheet 020255c...
Page 106: ...appliances 4 102 Camelot 2007 Notes...
Page 140: ...Section 5 Equipment 136 camelot 2007 Notes...
Page 155: ...151 Section 6 water systems camelot 2007 Water service center Typical Water System...
Page 156: ...Section 6 water systems 152 camelot 2007 Notes...
Page 186: ...Section 8 Electrical Systems House 182 camelot 2007 Notes...
Page 202: ...Section 9 Electrical Systems Chassis 198 camelot 2007 engine no start flow chart...
Page 244: ...Section 10 chassis information 240 camelot 2007 42 Tag Axle Models 070171i 070171j...
Page 258: ......