Section 7 — lp-GaS SyStemS
1
camelot 2007
2. Turn off
primary
valve
on the
LP-Gas
tank.
3.
Determine and repair the source of the
leak. If necessary, contact a qualified
professional for service.
WARNING
DO NOT operate any electric switch.
This can produce a spark and ignite the
gas.
CAUTION
DO NOT re-enter until the problem is
corrected.
Alarm Mute:
Press the
Test/Mute switch
when the detector
is in alarm.
1. The red LED will continue to flash and
the alarm will beep every 30 seconds
until the gas level has dropped to a safe
level.
2. The LED will flash green until the end
of the Mute cycle.
3. If dangerous gas levels return before
the end of the Mute cycle, the alarm
will beep four times and return to
phase 1.
4. After two minutes the detector will
return to normal operation (solid
green) or resound the alarm if
dangerous levels of gas remain in the
area.
Fault Alarm:
Should the microprocessor sense a fault in the
gas detector, a fault alarm will sound twice every
15 seconds. The LED will alternately flash red to
green and the
MUTE
switch will not respond to
any command. The gas detector must be repaired
or replaced.
Maintenance
1. Vacuum the dust off the detector
cover weekly (more frequently in
dusty locations) using the soft brush
attachment of a vacuum.
2.
DO NOT
spray cleaning agents or
waxes directly onto the front panel.
This action may damage the sensor,
cause an alarm or cause a detector
malfunction.
lp-gaS emergency proceDureS
cHecklISt
If you smell gas (a rotten egg or sulfur
smell) at any time, perform the following steps
immediately:
Shut off LP-Gas appliances.
Manually turn off the primary shut-off
valve at the LP-Gas tank.
DO NOT
operate any electric switch.
This can produce a spark and ignite the
gas.
Open windows and doors.
Evacuate the motorhome. Stay clear of
the surrounding area.
Keep all ignition sources out of the area.
Contact a qualified service technician to
find the source and repair the gas leak.
WARNING
A fire or explosion from ignited gas or
gas fumes can cause serious injury or
death.
lp-gaS tank
Measurement
Three methods can be used to
monitor the amount of fuel in
the LP-Gas tank: A small non-
adjustable gauge on the LP-Gas
tank (tank is located in a curbside
compartment) provides a quick
view of the LP-Gas level, the
Systems Control Monitor, located
in the hallway area, and the monitor panel
located in the water service center will also
provide the amount of fuel in the LP-Gas tank.
050250d
POTenTIal sOurCes OF lP-Gas leaks wHen OPeraTInG THe MOTOrHOMe
Cooktop burners
Oven
refrigerator
water Heater
Defective lP-Gas Connection
Defective regulator
Portable Propane Powered Appliances/Accessories
Furnace
050272
050256
Summary of Contents for Camelot 2007
Page 16: ......
Page 18: ......
Page 49: ...45 Section 2 Driving Safety Camelot 2007 Weight Record Sheet Actual Worksheet 020255b...
Page 53: ...49 Section 2 Driving Safety Camelot 2007 Weighing Procedure Worksheet 020255c...
Page 106: ...appliances 4 102 Camelot 2007 Notes...
Page 140: ...Section 5 Equipment 136 camelot 2007 Notes...
Page 155: ...151 Section 6 water systems camelot 2007 Water service center Typical Water System...
Page 156: ...Section 6 water systems 152 camelot 2007 Notes...
Page 186: ...Section 8 Electrical Systems House 182 camelot 2007 Notes...
Page 202: ...Section 9 Electrical Systems Chassis 198 camelot 2007 engine no start flow chart...
Page 244: ...Section 10 chassis information 240 camelot 2007 42 Tag Axle Models 070171i 070171j...
Page 258: ......