Mobeye argos i200 User Manual Download Page 9

4.4 SMS CUSTOM TEXT 

It is possible to add a custom text in the SMS text messages, to identify the Mobeye Argos

 

unit that sent the 

message. The second part of the SMS text message contains a standard text like ‘Mobeye alarm’, or ‘Test message 
OK’. The custom text will be written before the standard text. 
This custom text (max. 20 characters) is programmed by sending an SMS to the Mobeye Argos. Changing the 
custom text cannot be done via the keypad, only via sending an SMS text message. 
 
Switch the Mobeye Argos into the programming mode. In this mode the GSM module is switched on and is able to 
receive messages.  
 

 Enter your 4-

digit personal code. (factory setting: “1111”) 

 

Press “menu” 

 

Press “21” -> light turns green 

 

Press “OK” 

 
First the light flashes red (interval ca. 1 sec). As soon as the light turns green, the Mobeye Argos

 

is able to receive 

SMS-messages.  
 
To program the custom text, send an SMS in following structure: 

 
1111 NAME:myowntext 
 

-

 

‘1111’ stands for the installation code (1111) 

-

 

‘NAME’ is a standard command (capitals) 

-

 

Replace ‘myowntext’ by a self-defined text (max. 20 characters) 

-

 Be aware of the space after 1111 and the colon after NAME 

 
You will hear two short beeps in case of a correct command. 

 

Leave the menu by pressing “OK” twice. 
 
 

4.5 TELEPHONE NUMBERS 

Up to five telephone numbers can be programmed in to the Mobeye Argos. In the event of an alarm the Mobeye 
Argos first sends an SMS text message to all numbers, next they are called. It is possible to confirm the call, after 
which the other numbers will not be called anymore. Or to start a listen-in connection. 
Note: The first telephone number is required, the others are optional. 

4.6 SMS ON/OFF 

By default, the Mobeye Argos sends alarm notifications via text message and calls to the preset contact persons. 
By turning off the SMS, the unit will only call after the movement sensors sends an alarm. Regardless of this setting 
the temperature alarm always sends an SMS including the actual temperature.  

4.7 CALL ON/OFF 

By default, the Mobeye Argos sends alarm notifications via text message and calls to the preset contact persons. 
By turning off the CALL, the unit will only send an SMS text message as alarm notification. It is not possible to 
switch off both the SMS and the call. 

4.8 SENSOR SENSITIVITY 

The detectors’ sensitivity can be changed to a high or low value. 
 
1=  High 
2 = Low  
 
In the high sensitivity mode each detection will generate an alarm. In the lower sensitivity mode the alarm will be 
generated only when the detector is activated twice in any 15 second period. This mode prevents false alarms in 
case of e.g. draught and is most suitable if the sensor is directed towards an open space. 

4.9 ENTRY DELAY 

It is possible to choose from 5 entry delay times (1,15, 30, 45 and 60 seconds). The entry delay is the time between 
the moment of detection and the moment of sending the first SMS text message.  
Important note: If the GSM network has low signal strength, the time can be longer as the network connection may 
not be established within the time of the entry delay. 

Summary of Contents for argos i200

Page 1: ...Manual i200 Mobeye Argos SW version 6 n...

Page 2: ...g Not intended for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where an...

Page 3: ...9 4 15 Automatic time based arm disarm 9 4 16 Inactive time after a movement detection 9 5 Temperature alarm 10 5 1 Configuration 10 5 2 Monitoring the temperature limits 10 5 3 Adjusting the temperat...

Page 4: ...numbers 19 11 Mobeye Internet Portal 20 12 Programming via SMS text messages 21 12 1 Program mode 21 12 2 How to Program by SMS 21 13 Complete list of settings 22 14 Reports and lists 24 14 1 Status...

Page 5: ...he temperature reaches the limit Battery operated or using the mains Although the Mobeye Argos is designed to run on batteries it is possible to use an external power supply When powering the Mobeye A...

Page 6: ...e the cover slightly 2 2 STEP 2 INSERTING THE BATTERIES Insert the four lithium 3 0 volt batteries CR123 When replacing the batteries all settings remain unchanged After inserting the SIM card and the...

Page 7: ...nd user code are not interchangeable 3 2 ALARM MESSAGE CONFIRMATION AND LISTEN IN When the armed system detects a movement it first waits for the entry delay period and then it alarms During the entry...

Page 8: ...Interval test message 0 30 days 0 no message 07 Entry indication 0 off 1 beep on 2 LED on 0 off 08 Siren 0 off 1 on 0 off 09 Exit indication 0 off 1 on 1 on 12 SMS on off 0 off 1 on 1 on 13 Call on o...

Page 9: ...they are called It is possible to confirm the call after which the other numbers will not be called anymore Or to start a listen in connection Note The first telephone number is required the others a...

Page 10: ...a daily test message the exact time between the messages will be about 24 hours The smaller the interval between the test reports the shorter is the battery life The test message only works if the sy...

Page 11: ...nfirms this to you This function is active as soon as a temperature limit is programmed By resetting the limits the function becomes inactive 5 3 ADJUSTING THE TEMPERATURE The built in temperature sen...

Page 12: ...GOS The built in motion sensor has a 360 detection pattern and has a range of about 8 meters The Mobeye Argos can be positioned both vertically as horizontally It can be mounted to the wall put down o...

Page 13: ...phone number at memory position 01 will receive an SMS text message containing all existing GSM networks sorted by provider It also tells the strength of each network This search function can take a f...

Page 14: ...devices connected to it via the outputs when an event triggers it like an alarm or incoming call And although the Mobeye Argos is designed to run on batteries it is possible to use an external power...

Page 15: ...nstructions Enter your 4 digit code factory setting is 1111 Press menu light turns green Enter the menu number see list below Press OK Enter the new setting Press OK The light switches off a confirmat...

Page 16: ...ore an alarm is initiated If the input returns to the non alarm status within the delay time no alarm is sent The delay time can be set between 0 and 999 seconds As default the input delay time is set...

Page 17: ...list below Press OK Enter the new setting Press OK The light switches off a confirmation melody is played In the event of an incorrect entry the light turns red and a short beep sounds The menu can b...

Page 18: ...ng and remote control Remote control actions are arming disarming and switching the outputs As prerequisite for remote control the controlling telephone number needs to be authorised A maximum of ten...

Page 19: ...r your 4 digit code factory setting is 1111 Press menu light turns green Enter the menu number see list below Press OK Enter the new setting Press OK The light switches off a confirmation melody is pl...

Page 20: ...e senders telephone number needs to be authorised In the factory settings the switch behaviour of output 1 is set to RC 10 4 AUTHORISING TELEPHONE NUMBERS For remote control by telephone arm disarm sw...

Page 21: ...MS and or mail which are set in the portal Different persons can be set for alarm messages versus technical message 2 the name and location can be set in the portal This name is used in SMS and mail m...

Page 22: ...s After five minutes there is a time out and a beep is heard Leave the program mode earlier by pressing OK twice 12 2 HOW TO PROGRAM BY SMS Be sure the unit is in program mode Send an SMS message with...

Page 23: ...temperature Keypad 42 000 050 0 to 50 C 110 101 10 to 1 C 999 off off SMS HTL 10 to 50 Correction factor temperature Keypad 49 01 09 1 to 9 C 11 19 1 to 9 C 00 no correction 0 SMS TEMPOFFSET 9 tot 9...

Page 24: ...eypad 105 Telephone number SMS TEL5 Delete telephone number Keypad 101 105 0 SMS DEL1 DEL5 Authorise telephone number Keypad 201 210 Tel number SMS TELA1 TELA10 of ADDTELA Delete authorised number Key...

Page 25: ...as SMS text message 14 2 LIST OF SETTINGS The basic settings can be requested via CODE menu 10 OK or by sending an SMS with the content CODE SET The originator of the request receives the list of basi...

Page 26: ...lable belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes and then re enter the cor...

Page 27: ...1 V9 0 2 CENELEC EN 60950 2001 Mobeye B V Poeldonkweg 5 5216 JX s Hertogenbosch The Netherlands Name J P K van de Vijver Position Managing Director Signature Date 1 Augustus 2012 Support For support o...

Reviews: