9
4.10 ENTRY INDICATION
No entry indication is set as the factory default. It is possible to hear an indication beep during the entry delay. This
can be used as a reminder that the Mobeye is in active mode. It is also possible to just let the LED indicator flash a
few times, as an indication for the user.
4.11 SIREN
After the entry delay, the siren can sound for two minutes. At the same time the SMS text messages and telephone
calls will be sent. At soon as the Mobeye is switched off, the siren will stop. The siren is set to silent as the factory
default.
4.12 EXIT INDICATION
Upon arming the system, you have one minute to leave the room. The PIR is not active yet and an exit indication
sounds. It is possible to change this to a silent exit time. A short beep is heard and the LED flashes red during the
exit time.
4.13 INTERVAL TEST MESSAGE
The Mobeye Argos can send test messages. Through these
‘keep alive’ reports you will be informed about the
status of your Mobeye Argos. You can set the interval between the test reports.This is adjustable between 0 (no test
reported) and 30 (every 30 days a test message). Note: the interval of 1 day will result in a daily test message; the
exact time between the messages will be about 24 hours.
The smaller the interval between the test reports, the shorter is the battery life. The test message only works if the
system is on or a temperature limit is set.
4.14 SET ACTUAL TIME AND DATE
If the system is to be armed automatically, the internal clock time needs to be correct. Some Telecom providers
offer this in the network, to be synchronised by the Mobeye Argos during the start-up and after sending test
messages. It is possible to set the time and date manually. To view the clock time, send a list of the settings to the
first programmed phone number (CODE MENU 10 OK).
4.15 AUTOMATIC TIME-BASED ARM/DISARM
The Mobeye Argos can be armed and/or disarmed based on a daily time schedule. If the exit indication was set to
‘silent’, the system makes no noise during arming and disarming. The first telephone number needs to be set before
the arming and/or disarming time can be set.
4.16 INACTIVE TIME AFTER A MOVEMENT DETECTION
The
“PIR inactive time” is the time the movement sensor is inactive after having seen and reported movement. If the
time is set to
“5” (minutes), the sensor will only report new movements after a minimum of 5 minutes after the
previous movement.
The inactive time can be set in minutes from 0 to 999. As factory default the inactive time is set to
“5”.