22
13. COMPLETE LIST OF SETTINGS
Setting
Menu/
command
Options
Factory
default
Installation code
Keypad
00
4 digits
1111
SMS
INSTCODE:
Sensitivity PIR
Keypad
03
1 (high) of 2 (low)
1 (high)
SMS
SENS:
Entry delay
Keypad
04
1, 15, 30, 45 or 60
15
SMS
ENTRYDELAY:
Interval test message
Keypad
05
0, 1, 2, 3, … or 30 (days)
0
SMS
TEST:
Entry indication
Keypad
07
0 (off), 1 (on), (LED)
0 (OFF)
SMS
ENTRYBEEP:
ON, OFF, LED
Sirene
Keypad
08
0 (off), 1 (on)
0 (OFF)
SMS
SIREN:
ON, OFF
Exit indication
Keypad
09
0 (off), 1 (on)
1 (ON)
SMS
EXITBEEP:
ON, OFF
SMS on/off
Keypad
12
0 (off), 1 (on)
1 (ON)
SMS
SMSALARM:
ON, OFF
CALL on/off
Keypad
13
0 (off), 1 (on)
1 (ON)
SMS
CALLALARM:
ON, OFF
Select ARC
Keypad
30
00 (no), 01 (general)
00 (no)
SMS
ARC:
00, 01
ARC client number.
Keypad
31
5 digit client number
-
SMS
ARCCLIENTNR:
ARC telephone number
Keypad
32
Telephone number
-
SMS
ARCCALLERID:
Change minimum
temperature
Keypad
41
000-050 (0 to 50ºC)
110-101 (-10 to -1 ºC)
999 = off
off
SMS
LTL:
-10 to +50
Change maximum
temperature
Keypad
42
000-050 (0 to 50ºC)
110-101 (-10 to -1ºC)
999 = off
off
SMS
HTL:
-10 to +50
Correction factor
temperature
Keypad
49
01-09 (+1 to +9ºC)
11-19 (-1 to -9ºC)
00 (no correction)
0
SMS
TEMPOFFSET:
-9 tot +9
User code
Keypad
50
4 digits
8888
SMS
USERCODE:
Actual time
Keypad
60
hhmm
SMS
SETTIME:
Actual date
Keypad
61
yyyymmdd
SMS
SETDATE:
Automatic arming time
Keypad
62
hhmm
SMS
TIMEARM:
hhmm (delete by
“0”)
Automatic disarming time
Keypad
63
hhmm
SMS
TIMEDISARM:
hhmm
(delete by “0”)
PIR on/off
Keypad
70
0 (off), 1 (on)
1 (ON)
SMS
PIR:
ON, OFF
Input type input 1
Keypad
71
0 (off), 1 (NO), 2 (NC)
1 (NO)
SMS
TYPEIN1:
OFF, NO, NC
Input type input 2
Keypad
72
0 (off), 1 (NO), 2 (NC)
1 (NO)
SMS
TYPEIN2:
OFF, NO, NC
Inactive time
Input 1
Keypad
73
0..999 (min.)
5
SMS
INACTIVEINP1:
Inactive time
input 2
Keypad
74
0..999 (min.)
5
SMS
INACTIVEINP2:
Delay time input 1
Keypad
75
0..999 (sec.)
1
SMS
DELAY1:
Delay time input 2
Keypad
76
0..999 (sec.)
1
SMS
DELAY2:
Power failure delay time
Keypad
77
00..60 (min.)
1
SMS
DELAYPOW:
Delay temperature alarm
Keypad
78
00..60 (min.)
1
SMS
DELAYTEMP:
Inactive time PIR
Keypad
79
0..999 (min.)
5
SMS
INACTIVEPIR:
Pulse time output 1
Keypad
81
1..9999 (sec.)
0
SMS
TO1: