16
9. EXTERNAL POWER SUPPLY
Although the Mobeye Argos is designed to run on batteries, it is possible to use an external power supply (9-
24VDC). In this mode the module is always in connection with the GSM network. The advantage of external power
is the longer battery lifetime, to receive power failure messages and the possibility to perform remote actions, like
arm/disarm, switch the outputs, ask status reports and to program it via SMS-commands. Be aware: the PIR sensor
will be slightly less sensitive when using external power supply.
1)
Replace
the
white
grommet with the rubber
ring (using a tool)
2) Insert the 2 wires through the hole
to the inside part and in to the two
connectors (press the orange pins):
V+
to “+”
“Ground”
to “-“
3) Be sure the wires are
laid between the tapped
holes and the wall of the
casing before closing.
Article 10027:
black wire with white line is “+”, black wire is “-“
9.1 CONFIGURATION
To change the settings, please follow these instructions:
Enter your 4-digit code (factory setting is
“1111”)
Press “menu” - light turns green
Enter the menu number (see list below)
Press “OK”
Enter the new setting
Press “OK”. The light switches off, a confirmation melody is played
In the event of an incorrect entry, the light turns red and a short beep sounds. The menu can be left
from any position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
Description
Options
Factory setting
86
Power failure message
0 (off), 1 (on)
1 (on)
77
Power failure delay time
00..60 (min)
1
201…210
Authorise telephone number
Telephone number (0 to
delete)
9.2 SENSITIVITY PIR
Using an external power source, the internal PIR sensor will react slight slower after detecting movements, even
when the sensitivity is set to ‘high’. Be sure the sensor is positioned well, so the intruder can be seen while walking
or working. Please test the PIR positioning to ensure the PIR detects you in the areas you are trying to secure.
9.3 POWER FAILURE MESSAGE
Upon a power outage the batteries take over functioning. A ‘power failure’ SMS text message is sent to the first
telephone number. The GSM module turns to the low power status, meaning it closes and only establishes network
connection in case it needs to send a message (alarm, test, battery low).
The power failure message can be deactivated (OFF). As factory default the power failure message is set to
‘ON’.