![Mobeye argos i200 User Manual Download Page 24](http://html1.mh-extra.com/html/mobeye/argos-i200/argos-i200_user-manual_1814855024.webp)
23
CODE COMMAND:OPTION
CODE
COMMAND
:
OPTION
#
COMMAND
:
OPTION
#
COMMAND
:
OPTION
Setting
Menu/
command
Options
Factory
default
Pulse time siren/output 2
Keypad
82
1..9999 (sec.)
120
SMS
TO2:
Repeat
Keypad
84
0..99 (hours)
4
SMS
REPEAT:
Power failure message
Keypad
86
0 (off), 1 (on)
1 (ON)
SMS
POWERSMS:
ON / OFF
TEL1
Keypad
101
Telephone number
SMS
TEL1:
TEL2
Keypad
102
Telephone number
SMS
TEL2:
TEL3
Keypad
103
Telephone number
SMS
TEL3:
TEL4
Keypad
104
Telephone number
SMS
TEL4:
TEL5
Keypad
105
Telephone number
SMS
TEL5:
Delete telephone number
Keypad
101…105
0
SMS
DEL1….DEL5
Authorise telephone
number
Keypad
201…210
Tel. number
SMS
TELA1: ...TELA10:
of ADDTELA:
Delete authorised
number
Keypad
201…210
0
SMS
DELA:1..DELA:10
Behaviour
output 1
Keypad
83
1 (
RC
), 2 (
ARMED
), 3 (
DISARMED
), 4
(
INTRUDER
), 5 (
TEMP
)
1 (RC)
SMS
OUTPBEHAVIOR:
RC, ARMED, DISARMED, INTRUDER,
TEMP
Identification text
Keypad
-
SMS
NAME:
20 characters
Mobeye
Alarm text input 1
Keypad
-
SMS
TEXT1:
20 characters
Alarm 1
Alarm text input 2
Keypad
-
SMS
TEXT2:
20 characters
Alarm 2
Program method using the keypad:
CODE
menu
menu nr. OK option OK
Program method via SMS (in program mode):
Or several commands at once: