8. INPUTS
External sensors can be connected to the inputs. Upon closing (or opening) an input, the Mobeye Argos will send
an alarm message to the set alarm numbers (factory default: SMS and call).
1)
Replace
the
white
grommet with the rubber ring
(using a tool)
2) Insert the 2 wires of an external
sensor through the hole to the
inside and in to the two connectors
of input 1 (press the orange pins).
3) Be sure the wires are
laid between the tapped
holes and the wall of the
casing before closing.
When using a second input, connect this to input 2.
8.1 CONFIGURATION
To change the settings, please follow these instructions:
Enter your 4-digit code
(factory setting is “1111”)
Press “menu” - light turns green
Enter the menu number (see list below)
Press “OK”
Enter the new setting
Press “OK”. The light switches off, a confirmation melody is played
In the event of a incorrect entry, the light turns red and a short beep sounds. The menu can be left from any
position, by twice pressing “OK”.
Following settings are possible:
Menu
nr.
Description
Options
Factory setting
71
Input type input 1
0 (off), 1 (normally opened), 2
(normally closed)
1 (NO)
72
Input type input 2
0 (off), 1 (normally opened), 2
(normally closed)
1 (NO)
73
Inactive time input 1
0..999 (min.)
5
74
Inactive time input 2
0..999 (min.)
5
79
Inactive time PIR
00..60 (min.)
5
70
PIR on/off
0 (off), 1 (on)
1 (on)
75
Delay input 1
00..999 (sec.)
1
76
Delay input 2
00..999 (sec.)
1
84
Repeat time
0..99 (hours)
4