Service manual
drA
Drain test
Buttons
Button
Function
Display
Start of drain test
Back to the configuration
menu
Manual drain cooling on/off
In the lower display the actual drain temperature is displayed. By pressing the Start/stop button the test
is started. If the preheat button is pressed the drain solenoid is activated and the temperature should
drop (drain temperature only drops if the cooling water is significantly colder then the temperature
measured in the siphon).
100
100°C and core temperature calibration
Buttons:
Button
Function
Display
Start of calibration procedure
Back to the configuration
menu
Toggle between:
Electric version:
Offset / chamber temperature/
heating power in %
Gas version:
Offset / chamber temperature/
Gas fan rpm´s
Notice: The core temperature and external reference probe must be placed in the centre of the cooking
chamber. The probes have to be pointed upwards to prevent water droplet discharge on the probes.
We recommend using a grid for probe placement.
41
drA
25
Drain test
Drain temperature
CaL
100°C + CT calibration