Check-up of the connection pressure (operating pressure)
6.x–20.x
Leak test
Prior to checking the connection pressure, all connection points both outside and inside the
appliance must be checked for leaks according to the technical regulations governing gas installations
(TRGI) (using a gas detector or leak spray).
Checking the connection pressure
➢
Close the on site gas valve.
➢
Disconnect the unit from the power supply
(remove fuses or pull the connection-plug)
➢
Unscrew the two screws which are located
down on the left to remove the left side
panel.
➢
Unscrew the sealing screw from the
pressure measurement connection on the
gas valve
„IN“
and connect a manometer.
The manometer used should be accurate to
at least 0.1 mbar.
➢
Open the on site gas valve and connect
power supply.
➢
Start-up the appliance.
➢
Measure the connection pressure and
compare it to the table below.
➢
After measuring the pressure and with the
shut-off valve still closed, refit the sealing
screw in the pressure measuring point and
check for leaks.
Type of gas
Nominal connection pressure
Measured
connection pressure
Natural Gas E, LL (20 mbar)
15,0 – 25,0 mbar
Liquid gas B, P (50 mbar)
15,0 – 57,5 mbar
22
Use only TGRI-approved, foam forming agents! Do not spray leak spray onto the wires of
the ignition electronics!