Service manual
Parameter list
No.
Description
Setting range
Function
000
Time/ Date (Option)
Time / Date
Adjustment of time an date
006
Temperature reading in
C
,
F
(
C
default)
Adjustment of temperature reading in °C / °F
082
Preheat factor
0
–
30
(
15
% default)
Preheat factor if using the preheat function.
The factor will added to the selected
temperature (example: 100°C adjusted =
preheating up to 115°C). This happens under
consideration of the maximum temperature
values
032
Time delay fan
Off
/
On
(
Off
default)
When On, the fan runs during the time delay
to cool the oven chamber with a block of ice
in the bottom drawer. For this purpose, place
the perforated container in the closed
container, fill with approximately 4 litres of
water and allow to freeze. Insert the ice
block into the perforated container at the
lowest level. This allows a temperature of
57°F to be maintained for up to 6 hours.
(Contact service technician)
024
Cooling water
(drain cooling)
Lo
/
Std
/
Hi
(
Std
default)
Setting
Lo
: Less water consumption but
higher drain temperature and more steam from
the exhaust pipe.
Setting
Hi
: More water consumption but
lower drain temperature and less steam from
the exhaust pipe.
083
Time ext. hood
( in seconds
0
–
600
Time where the external condensation hood
runs to maximum performance after the
chamber door was opened.
084
Time of signal
(in seconds)
0
–
180
(
20
default)
Time of the buzzer at the end of a program.
0= buzzer off.
015
Altidude
0
= 0 – 500 m
1
= 501 – 1000 m
2
= 1001 – 1500 m
3
= > 1501 m
(
0
default)
Altitude adjustment (above sea level).
47