Service manual
Continuation CO2 calibration
Cooking chamber temperature
After the burner has ignited (lower display shows 11)
press the preheating button to show the cooking
chamber temperature.
➢
The upper display shows the actual cooking chamber
temperature e. g.
85
(°C/°F).
➢
The lower display shows the rpms of the gas blower
divided by 10 e.g.
280
for 2800 rpm.
CO
2
measurement
If the cooking chamber has a approximate temperature
of 150°C and the rpm show the values according
to the table check the CO
2
value.
Fan speed in rpm for high (Hi) power and low power (Lo)
Model
Hi, Hi1, Hi2
Lo, Lo1, Lo2
6.1
5050
4800
6.2
6700
5300
10.1
5050
2800
10.2
6700
2800
20.1
5050
2800
20.2
6700
2800
Place the CO
2
probe into the exhaust pipe. For correct
measurement do not place the probe during the ignition
process. Be sure to place the probe into the correct
pipe for two chamber models. The C0
2 value
has
to be within the range according to the table. Take
care that the cooking chamber temperature does not
exceed 200°C. If the temperature reaches 250°C the
procedure is automatically stopped.