Service manual
Overview of the error messages
Error message
Description
Err 1
Error core temperature probe
Err 2
Error chamber probe 1
Err 3
Error chamber probe 2
Err 4
Core temperature probe not calibrated
Err 5
Error drain probe
Err 7
Error reference probe on board defect
Err 8
Risk of ice
Err 9
Overtemperature cooking chamber
Err 10
Overtemperature electronic
Err 11
Electronic too hot
Err 20
Core temp. replace not possible
Err 30
*
No fan 1
Err 31
*
Fan runs
Err 32
*
No fan 2
Err 33
*
Fan direction wrong
Err 36
*
Jumper setting at frequency controller wrong
Err 40
Not authorized access
Err 66
**
No water
Err 71
*
No gas 1
Err 710
*
No gas 2
Err 72
*
No gas fan 1
Err 720
*
No gas fan 1
Err 73
*
General gas fault 1
Err 730
*
General gas fault 2
Err 74
*
No flame 1
Err 740
*
No flame 2
Err 101
***
Battery empty
Err 120
12 Volt ground error
Err 121
UREF0. Ground error at probe or pcb
SHO
Demo mode
-n-
Emergency program
-c-
Carry out unit configuration in the service area
*
= Only at Gas units
*
*
= Only at units with WaveClean
**
*
= Only at units with gas and communication pcb
2
Summary of Contents for HansDampf 10.1
Page 4: ...Service manual 4...
Page 6: ...Service manual Keypad and displays of the HansDampf Silver 2 6...
Page 20: ...Service manual Gas orifices and fan speeds 20...
Page 71: ......
Page 72: ......