App. - 16 App. - 16
APPENDIXES
Address
Decimal (Hex)
Protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi Pd
Registration
Reference
16396
(400C
H
)
16428
(402C
H
)
Matched receive packet No. 1
0: No matched receive packet
1 to 16: Matched receive packet No.
16397
(400D
H
)
16429
(402D
H
)
Matched receive packet No. 2
16398
(400E
H
)
16430
(402E
H
)
Matched receive packet No. 3
16399
(400F
H
)
16431
(402F
H
)
Matched receive packet No. 4
16400
(4010
H
)
16432
(4030
H
)
Matched receive packet No. 5
16401
(4011
H
)
16433
(4031
H
)
Matched receive packet No. 6
16402
(4012
H
)
16434
(4032
H
)
Matched receive packet No. 7
16403
(4013
H
)
16435
(4033
H
)
Predefined
protocol function
control data
specification
Matched receive packet No. 8
0
—
R Not
allowed
—
16404 to
16415
(4014
H
to
401F
H
)
16436 to
16447
(4034
H
to
403F
H
)
Use prohibited
System area
—
16448
(4040
H
)
16464
(4050
H
)
Predefined
protocol function
control data
specification
Protocol cancel
0: No cancel instruction
1: Cancel request (set by user)
2: Cancel completed (set by C24)
0
—
RW Not allowed
GX Works2
Version 1
Operating
Manual
(Intelligent
Function
Module)
16449
(4041
H
)
16465
(4051
H
)
Execution status
0: Unexecuted
1: Waiting for transmission
2: Sending
3: Waiting for data reception
4: Receiving
5: Completed
0 — R
16450
(4042
H
)
16466
(4052
H
)
Predefined protocol function error code
0: Normal
Other than 0: Error (error code)
0 — R
Section 13.2
Section 15.2
16451
(4043
H
)
16467
(4053
H
)
Checking
predefined
protocol function
execution status
Number of protocol executions
0: No log
1 to 65535: Number of executions
0 — R
Not allowed
—
16452 to
16463
(4044
H
to
404F
H
)
16468 to
16479
(4054
H
to
405F
H
)
Use prohibited
System area
—
16480 to 16517
(4060
H
to 4085
H
)
Use prohibited
System area
—
16518(4086
H
)
Protocol No.
1 to 128: Protocol No.
65535: Unidentified
0 —
R
16519(4087
H
)
Setting type
0: Packet setting or element setting
1: Protocol detailed setting
65535: Not specified
0 —
R
16520(4088
H
)
Packet No.
0: Send packet
1 to 16: Receive packet
65535: Unidentified
Valid when the Setting type value is 0.
0 —
R
16521(4089
H
)
Protocol setting
data error
information
Element No.
1 to 32: Element No.
65535: Unidentified
Valid when the Setting type value is 0.
0 —
R
Not allowed
Section 9.3
Section 15.2.2
Summary of Contents for MELSEC LJ71C24
Page 1: ......
Page 2: ......
Page 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Page 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Page 23: ...A 21 A 21 MEMO...
Page 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Page 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Page 425: ......
Page 426: ......
Page 427: ......