12 - 35 12 - 35
12 DEDICATED INSTRUCTIONS
(4) The status of the CSET instruction, whether it is being executed or completed
normally/abnormally, can be checked by the complete device (D2) specified by
the setting data.
(a) Complete device ((D2) + 0)
This device turns on at the End processing of the scan at which the CSET
instruction is completed and turns off at the next End processing.
(b) Complete device ((D2) + 1)
It turns on/off by the status at which the CSET instruction is completed.
• At normal completion: It is kept turned off and does not change.
• At abnormal completion: It turns on at the END processing of the scan at
which the CSET instruction is completed and
turns off at the next END processing.
[Operation at execution of CSET instruction]
Scan
Sequence program
C24
At abnormal completion
End
processing
Scan
Scan
CSET instruction
Complete device
Complete 1
Execution of instruction
Setting processing
End
processing
End
processing
Error
(1) If the dedicated instruction is abnormally completed, the error flag (SM0) turns on
and the error code is stored in SD0.
Refer to the following according to the error code, and check/take action according
to the error.
<Error code>
4FFF
H
or less: MELSEC-L CPU Module User's Manual (Hardware Design,
Maintenance and Inspection)
7000
H
or later: Section 15.2
Summary of Contents for MELSEC LJ71C24
Page 1: ......
Page 2: ......
Page 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Page 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Page 23: ...A 21 A 21 MEMO...
Page 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Page 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Page 425: ......
Page 426: ......
Page 427: ......