9 - 20 9 - 20
9 DATA COMMUNICATION USING THE PREDEFINED PROTOCOL
4) "Conversion Unit": Doubleword,
"Number of Decimals": Variable Point
For 'Variable Point', the decimal point position is set in the data storage
area.
Data storage area
Numeric data
Decimal point position
(L)
(H)
(L)
(H)
0h
1h
2h
3h
In the decimal point position area, the decimal point position is set as
follows.
Send/receive data
(number of digits is 10)
Numeric data
Decimal point position
1234567890 1234567890(499602D2
H
) 1(1
H
)
123456789.0 1234567890(499602D2
H
) 10(0A
H
)
12345678.90 1234567890(499602D2
H
) 100(64
H
)
1234567.890 1234567890(499602D2
H
) 1000(3E8
H
)
: : :
1.234567890 1234567890(499602D2
H
) 1000000000(3B9ACA00
H
)
(e) Range of value that can be used in the data storage area
The following table shows the range of value that can be used in the data
storage area.
Conversion
Sign
Conversion unit
Range of value
Word
0 to 65535 (0
H
to FFFF
H
)
Unsigned
Double word
0 to 4294967295
(0
H
to FFFFFFFF
H
)
Word
-32768 to 32767
(8000
H
to FFFF
H
, 0
H
to 7FFF
H
)
HEX ASCII decimal
ASCII decimal HEX
Signed
Double word
-2147483648 to 2147483647
(80000000
H
to FFFFFFFF
H
,
0
H
to 7FFFFFFF
H
)
Word 0
H
to FFFF
H
HEX ASCII hexadecimal
ASCII hexadecimal HEX
Double word
0
H
to FFFFFFFF
H
Summary of Contents for MELSEC LJ71C24
Page 1: ......
Page 2: ......
Page 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Page 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Page 23: ...A 21 A 21 MEMO...
Page 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Page 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Page 425: ......
Page 426: ......
Page 427: ......