App. - 12 App. - 12
APPENDIXES
Address
Decimal (Hex)
Protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi Pd
Registration
Reference
8210
(2012
H
)
8466
(2112
H
)
Transmission control start free area designation
64 to 4,095: transmission control start free area
64
8211
(2013
H
)
8467
(2113
H
)
Transmission control end free area designation
263 to 4096: transmission control end free area
263
RW
User’s Manual
(Application)
Nonprocedural and non reception monitoring time format
designation
8212
(2014
H
)
8468
(2114
H
)
For transmission
control
designation
0: Format-0
1: Format-1
0
—
RW
—
Allowed
User’s Manual
(Application)
8213 to
8215
(2015
H
to
2017
H
)
8469 to
8471
(2115
H
to
2117
H
)
Use prohibited
System area
—
8216
(2018
H
)
8472
(2118
H
)
Communication data monitoring designation
0000
H
: No monitor/stopped monitor designation
0001
H
: Monitor start designation
0002
H
: Monitoring (C24 is a set.)
1002
H
: Monitoring stopped (C24 is set.)
100F
H
: Monitor setting error (C24 is a set.)
0
8217
(2019
H
)
8473
(2119
H
)
Data optional designation
0: Off 1: On
Full stop designation (b0)
Timer 0 errors at occurrence stop designation (b2)
For system (b1), (b3) to (b15)
0
8218
(201A
H
)
8474
(211A
H
)
Monitor buffer head address designation
(400
H
to 1AFD
H
,2600
H
to 3FFD
H
)
CH1:
2600
H
CH2:
3300
H
8219
(201B
H
)
8475
(211B
H
)
Communication
data monitoring
function
Monitor buffer size designation
(0003
H
to 1A00
H
)
0D00
H
RW Allowed
User’s Manual
(Application)
8220 to
8223
(201C
H
to
201F
H
)
8476 to
8479
(211C
H
to
211F
H
)
Use prohibited
System area
—
User frame receive format designation (1st to 4th)
8224 to
8227
(2020
H
to
2023
H
)
8480 to
8483
(2120
H
to
2123
H
)
0: Format-0,
1: Format-1
8228 to
8231
(2024
H
to
2027
H
)
8484 to
8487
(2124
H
to
2127
H
)
For designation
of user frame
receiving method
Exclusive format-1 received data count (1st to 4th)
0 or more: Exclusive format-1 received data count
0
—
RW
—
Allowed
Section 7.2
User's Manual
(Application)
8232 to
8239
(2028
H
to
202F
H
)
8488 to
8495
(2128
H
to
212F
H
)
Use prohibited
System area
—
Transmission transparent code designation (2nd to 4th)
0000
H
Other than 0000
H
:No designation
:Designated (below)
8240 to
8248
(2030
H
to
2038
H
)
8496 to
8504
(2130
H
to
2138
H
)
For designation
of transparent
code
• Transparent code (b0 to b7)
00
H
to FF
H
: Transparent code
• Additional code (b8 to b15)
01
H
to FF
H
: Additional code
0
—
RW
—
Allowed
Section 7.2
User's Manual
(Application)
8249 to
8255
(2039
H
to
203F
H
)
8505 to
8511
(2139
H
to
213F
H
)
Use prohibited
System area
—
Cycle time units designation
8256
(2040
H
)
8512
(2140
H
)
0: 100 ms
1: s
2: min
2
Cycle time designation
8257
(2041
H
)
8513
(2141
H
)
0
H
: No designation
1
H
to FFFF
H
: Programmable controller CPU monitoring cycle
time
5
H
Programmable controller CPU monitoring function designation
0: Do not use the function.
1: Fixed cycle transmission
8258
(2042
H
)
8514
(2142
H
)
2: Condition agreement transmission
0
Programmable controller CPU monitoring transmission measure
designation
8259
(2043
H
)
8515
(2143
H
)
For designation
of programmable
controller CPU
monitoring
function
0: Data transmission (device data and CPU status data)
0
R — Allowed
User's Manual
(Application)
Summary of Contents for MELSEC LJ71C24
Page 1: ......
Page 2: ......
Page 18: ...A 16 A 16 INDEX REVISIONS WARRANTY...
Page 22: ...A 20 A 20 2 LJ71C24 R2 LJ71C24 R2 Before Using the Product...
Page 23: ...A 21 A 21 MEMO...
Page 38: ...4 2 4 2 4 PROCEDURES PRIOR TO OPERATION MEMO 4...
Page 105: ...7 30 7 30 7 SETTINGS FOR THE C24 MEMO...
Page 425: ......
Page 426: ......
Page 427: ......