11 - 195 11 - 195
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
Format 2 control table
%(0)
• • • • • •
Format 2 control table
• Specify 256.
%(1)
• • • • • •
Specify the number of the network to be accessed.
See Section 4.2.2 for the allowable specification range.
%(2)
• • • • • •
Specify the station number of the PLC CPU from which
data is to be read.
See Section 4.2.2 for the allowable specification range.
%(3)
• • • • • •
Detailed error codes are stored here.
See Appendix 4.4.2 for the details about the error codes.
%(4)
• • • • • •
Processing code
• Specify 9.
%(5)
• • • • • •
Specify the microcomputer program to be loaded.
• To load the main microcomputer program
• • • • •
Specify 1.
• To load a sub-microcomputer program
• • • • •
Specify 2.
Always specify 1 for PLC CPUs in which sub-
microcomputer programs cannot be used.
%(6)
• • • • • •
Specify the starting addresses of the microcomputer
program to be loaded.
The maximum number of bytes in the microcomputer
program that can be specified is the capacity set by the
parameter.
%(7)
• • • • • •
Specify the number of bytes to be read.
The allowable specification range is from 1 to 128 bytes.