11 - 317 11 - 317
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
Program Example
(1) Program example for a format 1 control table
100 ' A program example that stops a PLC CPU on a remote station
110 DIM TBL%(10), A%(10)
:
' Defines arrays
120 TBL%(0) = 255
:
' Specifies the station number to
communicate with to the local station
130 TBL%(1) = 16
:
' Specifies to perform remote STOP to a
PLC CPU
140 PCWT TBL%( ), A%( )
:
' Executes the remote STOP
150 END
(2) Program example for a format 2 control table
100 ' A program example that stops a PLC CPU on a remote station
110 DIM TBL%(10), A%(10)
:
' Defines arrays
120 TBL%(0) = 256
:
' Specifies a format 2 control table
130 TBL%(1) = 1
:
' Specifies network number 1
140 TBL%(2) = 1
:
' Specifies station number 1
130 TBL%(3) = 16
:
' Specifies to perform remote STOP to a
PLC CPU
140 PCWT TBL%( ), A%( )
:
' Executes the remote STOP
15 END