11 - 183 11 - 183
MELSEC-Q
11 INSTRUCTIONS AND FUNCTIONS
Program Example
(1) Program example for a format 1 control table
100 'A program example that reads extension file registers registered to be monitored by the PCWT
instruction
110 DIM TBL1%(10), A%(20), TBL2%(10), B%(20)
:
'Defines arrays
120 TBL1%(0)=255
:
'Specifies the station number to
communicate with to the local station
130 TBL1%(1)=5
:
'Specifies to register extension file registers
to be monitored
140 TBL1%(2)=2
:
'Specifies the number of points to be
monitored
150 A%(0)=1:A%(1)=0
:
'Specifies block number 1 and device
number 0
160 A%(2)=1:A%(3)=1
:
'Specifies block number 1 and device
number 1
170 PCWT TBL1%( ),A%( )
:
'Executes the monitor registration
180 TBL2%(0)=255
:
'Specifies the station number to
communicate with to the local station
190 TBL2%(1)=5
:
'Specifies to read the extension file
registers registered to be monitored by the
PCWT instruction
200 PCRD TBL2%( ),B%( )
:
'Executes the read operation
210 PRINT"B%(0)=";B%(0)
:
'Displays the result
220 PRINT"B%(1)=";B%(1)
230 END