(2) Program example for format 2 control table
100 'A program example that reads device memory registered to be monitored by the PCWT
instruction
110 DIM TBL1%(10), A%(20), TBL2%(10), B%(20)
:
'Defines arrays
120 A%(0)=1:A%(1)=0
:
'Registers X000 to X015 to be monitored
130 A%(2)=2:A%(3)=16
:
'Registers Y016 to Y031 to be monitored
140 A%(4)=3:A%(5)=96
:
'Registers M096 to M113 to be monitored
150 A%(6)=7:A%(7)=0
:
'Registers T000 (contact) to be monitored
160 A%(8)=18:A%(9)=48
:
'Registers D048 to be monitored
170 TBL1%(0)=256
:
'Specifies a format 2 control table
180 TBL1%(1)=1
:
'Specifies network number 1
190 TBL1%(2)=1
:
'Specifies station number 1
200 TBL1%(4)=2
:
'Specifies to monitor registered device
memory
210 TBL1%(5)=2
:
'Specifies word units
220 TBL1%(6)=5
:
'Specifies the number of device points to be
monitored
230 PCWT TBL1%( ),A%( )
:
'Executes the monitor registration
240 TBL2%(0)=256
:
'Specifies a format 2 control table
250 TBL2%(1)=1
:
'Specifies network number 1
260 TBL2%(2)=1
:
'Specifies station number 1
270 TBL2%(4)=2
:
'Specifies to read devices registered to be
monitored by the PCWT instruction
280 PCRD TBL2%( ),B%( )
:
'Executes the read operation
290 PRINT "Status of X000 to X015=&H";HEX$(B%(0)) :
'Displays the result
300 PRINT "Status of Y016 to Y031=&H";HEX$(B%(1))
310 PRINT "Status of M096 to M113=&H";HEX$(B%(2))
320 PRINT "Status of T000 (contact)=&H";HEX$(B%(3))
330 PRINT "Data in D048=";B%(4)